Beat-to-beat estimate of fetal cardiac time intervals using magnetocardiography: longitudinal charts of normality ranges and individual trends.

نویسندگان

  • Silvia Comani
  • Marco Liberati
  • Dante Mantini
  • Biagio Merlino
  • Giovanna Alleva
  • Elisabetta Gabriele
  • Silvano Di Luzio
  • Gian Luca Romani
چکیده

BACKGROUND Fetal magnetocardiography (fMCG) records fetal cardiac electro-physiological activity during the second half of gestation. We aimed at assessing normality values, related variability, and trends of fetal cardiac time intervals (fCTI) evaluated longitudinally from beat-to-beat fMCG analysis in uncomplicated pregnancies. MATERIALS AND METHODS The fMCG were recorded with multi-channel system in shielded room. FCTI were estimated on more than 2600 fetal cardiac cycles from 51 fMCG data sets of uncomplicated pregnancies. Independent component analysis (ICA) allowed reconstructing reliable fetal signals for beat-to-beat identification of fCTI (RR, P wave, PQ, PR, QT, QTc, QRS, ST, and T wave); intra-individual variability analysis and trends were calculated; reference longitudinal charts accounted for intra- and inter-individual variations and were compared with figures estimated on averaged signals. RESULTS For each data set, fCTI were calculated beat-to-beat on rhythm strips of more than 50 beats (95% overall detection rate). FCTI values, variability, and trends were in good agreement with available reference figures; intervals related to P and T waves were, respectively, underestimated and overestimated with respect to those estimated on averaged signals or obtained by other research groups. Errors were reduced and individual trends could be drawn. CONCLUSIONS ICA permitted the reconstruction of reliable time course of fetal cardiac signals and the beat-to-beat calculation of time intervals, and normality ranges, with smaller errors with respect to previous studies. The retrieval of fetal traces with clear morphology and the longitudinal character of the study allowed estimating individual trends and beat-to-beat characterization, impossible with cross-sectional studies on averaged beats.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Assessment of left ventricular pre-ejection period in the fetus using simultaneous magnetocardiography and echocardiography.

INTRODUCTION Fetal magnetocardiography (fMCG) is a promising new technique for assessing fetal rhythm; however, no prior studies have utilized fMCG to evaluate human fetal electromechanical physiology. Pre-ejection period (PEP) is an important measure of the electromechanical activation of the heart, and is altered by disease states and arrhythmias. MATERIALS AND METHODS A novel technique was...

متن کامل

A novel technique for fetal heart rate estimation from Doppler ultrasound signal

BACKGROUND The currently used fetal monitoring instrumentation that is based on Doppler ultrasound technique provides the fetal heart rate (FHR) signal with limited accuracy. It is particularly noticeable as significant decrease of clinically important feature - the variability of FHR signal. The aim of our work was to develop a novel efficient technique for processing of the ultrasound signal,...

متن کامل

Effect of endotoxemia on heart rate dynamics in rat isolated perfused hearts

Introduction: Beat-to-beat variation in heart rate shows a complex dynamics, and this complexity is changed during systemic inflammatory response syndrome (e.g. sepsis). It is not known whether or not cardiac pacemaker dynamical rhythm is affected by sepsis. The aim of this study was to investigate heart rate dynamics of isolated heart as well as expression of pacemaker channels (HCN) in a r...

متن کامل

A Hybrid EMD-Kurtosis Method for Estimating Fetal Heart Rate from Continuous Doppler Signals

Monitoring of fetal heart rate (FHR) is an important measure of fetal wellbeing during the months of pregnancy. Previous works on estimating FHR variability from Doppler ultrasound (DUS) signal mainly through autocorrelation analysis showed low accuracy when compared with heart rate variability (HRV) computed from fetal electrocardiography (fECG). In this work, we proposed a method based on emp...

متن کامل

Beat-to-beat analysis method for magnetocardiographic recordings during interventions.

Multichannel magnetocardiography (MCG) during exercise testing has been shown to detect myocardial ischaemia in patients with coronary artery disease. Previous studies on exercise MCG have focused on one or few time intervals during the recovery period and only a fragment of the data available has been utilized. We present a method for beat-to-beat analysis and parametrization of the MCG signal...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Acta obstetricia et gynecologica Scandinavica

دوره 84 12  شماره 

صفحات  -

تاریخ انتشار 2005