Development of a dual modality imaging system

نویسندگان

  • Jin Ho Jung
  • Yong Choi
  • Key Jo Hong
  • Byung Jun Min
  • Joon Young Choi
  • Yearn Seong Choe
  • Kyung-Han Lee
  • Byung-Tae Kim
چکیده

Several groups have reported the development of dual modality Gamma camera/optical imagers, which are useful tools for investigating biological processes in experimental animals. While previously reported dual modality imaging instrumentation usually employed a separated gamma camera and optical imager, we designed a detector using a position sensitive photomultiplier tube (PSPMT) that is capable of imaging both gamma rays and optical photons for combined gamma camera and optical imager. The proposed system consists of a parallel-hole collimator, an array-type crystal and a PSPMT. The top surface of the collimator and array crystals is left open to allow optical photons to reach the PSPMT. Pulse height spectra and planar images were obtained using a Tc-99m source and a green LED to estimate gamma and optical imaging performances. When both gamma rays and optical photon signals were detected, the signal interferences caused by each other signal were evaluated. A mouse phantom and an ICR mouse containing a gamma ray and optical photon source were imaged to assess the imaging capabilities of the system. The sensitivity, energy resolution and spatial resolution of the gamma image acquired using Tc-99m were 1.1 cps/kBq, 26% and 2.1 mm, respectively. The spatial resolution of the optical image acquired with an LED was 3.5 mm. Signal-to-signal interference due to the optical photon signal in the gamma pulse height spectrum was negligible. However, the pulse height spectrum of the optical photon signal was found to be affected by the gamma signal, and was obtained between signals generated by gamma rays with a correction using a veto gate. Gamma ray and optical photon images of the mouse phantom and ICR mouse were successfully obtained using the single detector. The experimental results indicated that both optical photon and gamma ray imaging are feasible using a detector based on the proposed PSPMT. 0031-9155/09/144547+13$30.00 © 2009 Institute of Physics and Engineering in Medicine Printed in the UK 4547

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiolabeling and Biodistribution of new dual modality nanoparticle probe in Nuclear Medicine

Introduction: Dual-modality contrast agents, such as radiolabeled nanoparticles, are promising candidates for a number of diagnostic applications, namely SPECT imaging with MR imaging. So the aim of study was evaluating potential of Chitosan-Coated Magnetic Nanoparticles(SPION) labeled with 99mTc as new Dual-modality probes for liver Imaging. Materials and Methods:</st...

متن کامل

Employing dual frequency phase sensitive demodulation technique to improve the accuracy of voltage measurement in magnetic induction tomography and designing a labratoary prototype

Magnetic induction tomography (MIT) is a promising modality for noninvasive imaging due to its contactless technology. Being a non-contact safe imaging technique, MIT has been an appropriate method in compare to other electrical tomography. In this imaging method, a primary magnetic field is applied by excitation coils to induce eddy currents in the material to be studied and a secondary magnet...

متن کامل

Development of 153Sm-DTPA-SPION as a theranostic dual contrast agents in SPECT/MRI

Objective(s): This study describes the preparation, biodistribution of 153Sm-DTPA-SPION after intravenous injection in rats. Materials and Methods: The chelator DTPA dianhydride was conjugated to SPION using a small modification of the well-known cyclic anhydride method. Conjugation was done at a 1: 4 (SPION: ccDTPA) molar ratio. Conjugation reaction was purified with magnetic assorting column...

متن کامل

Computed tomography based attenuation correction in PET/CT: Principles, instrumentation, protocols, artifacts and future trends

  The advent of dual-modality PET/CT imaging has revolutionized the practice of clinical oncology, cardiology and neurology by improving lesions localization and the possibility of accurate quantitative analysis. In addition, the use of CT images for CT-based attenuation correction (CTAC) allows to decrease the overall scanning time and to create a noise-free attenuat...

متن کامل

Carbon-11 radiolabeling of iron-oxide nanoparticles for dual-modality PET/MR imaging.

Dual-modality imaging, using Magnetic Resonance Imaging (MRI) and Positron Emission Tomography (PET) simultaneously, is a powerful tool to gain valuable information correlating structure with function in biomedicine. The advantage of this dual approach is that the strengths of one modality can balance the weaknesses of the other. However, success of this technique requires developing imaging pr...

متن کامل

Application prospective of nanoprobes with MRI and FI dual-modality imaging on breast cancer stem cells in tumor

Breast cancer (BC) is a serious disease to threat lives of women. Numerous studies have proved that BC originates from cancer stem cells (CSCs). But at present, no one approach can quickly and simply identify breast cancer stem cells (BCSCs) in solid tumor. Nanotechnology is probably able to realize this goal. But in study process, scientists find it seems that nanomaterials with one modality, ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009