Fast contact-mode atomic force microscopy on biological specimen by model-based control.

نویسندگان

  • G Schitter
  • R W Stark
  • A Stemmer
چکیده

The dynamic behavior of the piezoelectric tube scanner limits the imaging rate in atomic force microscopy (AFM). In order to compensate for the lateral dynamics of the scanning piezo a model based open-loop controller is implemented into a commercial AFM system. Additionally, our new control strategy employing a model-based two-degrees-of-freedom controller improves the performance in the vertical direction, which is important for high-speed topographical imaging. The combination of both controllers in lateral and vertical direction compensates the three-dimensional dynamics of the AFM system and reduces artifacts that are induced by the systems dynamic behavior at high scan rates. We demonstrate this improvement by comparing the performance of the model-based controlled AFM to the uncompensated and standard PI-controlled system when imaging pUC 18 plasmid DNA in air as well as in a liquid environment.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effective Parameters in Contact Mechanic for Micro/nano Particle Manipulation Based on Atomic Force Microscopy

The effect of geometry and material of the Micro/Nano particle on contact mechanic for manipulation was studied in this work based on atomic force microscopy. Hertz contact model simulation for EpH biological micro particle with spherical, cylindrical, and circular crowned roller shape was used to investigate the effect of geometry on contact simulation process in manipulation. Then, to val...

متن کامل

Fourier transformed atomic force microscopy: tapping mode atomic force microscopy beyond the Hookian approximation

The periodic impact force induced by the tip–sample contact in tapping mode atomic force microscopy (TM-AFM) gives rise to anharmonic oscillations of the sensing cantilever. These anharmonic signals can be understood with a model which goes beyond the common Hookian approximation: the cantilever is described as a multiple degree of freedom system. A theoretical analysis of the anharmonic signal...

متن کامل

Effects of relative humidity and applied force on atomic force microscopy images of the filamentous phage fd.

The filamentous phage fd was studied by both contact- and tapping-mode atomic force microscopy under conditions of controlled variations in relative humidity and changes in the applied tip force. By spin-coating freshly cleaved mica with phage containing solutions having very low salt content followed by rapid humidity control, stable and reliable sample preparation was achieved. The apparent h...

متن کامل

Tip Effect of the Tapping Mode of Atomic Force Microscope in Viscous Fluid Environments

Atomic force microscope with applicable types of operation in a liquid environment is widely used to scan the contours of biological specimens. The contact mode of operation allows a tip to touch a specimen directly but sometimes it damages the specimen; thus, a tapping mode of operation may replace the contact mode. The tapping mode triggers the cantilever of the microscope approximately at re...

متن کامل

Minimizing tip-sample forces in jumping mode atomic force microscopy in liquid.

Control and minimization of tip-sample interaction forces are imperative tasks to maximize the performance of atomic force microscopy. In particular, when imaging soft biological matter in liquids, the cantilever dragging force prevents identification of the tip-sample mechanical contact, resulting in deleterious interaction with the specimen. In this work we present an improved jumping mode pr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Ultramicroscopy

دوره 100 3-4  شماره 

صفحات  -

تاریخ انتشار 2004