Case presentation: implantation of cardiac resynchronization therapy pacemaker via the coronary sinus in a patient with triple valve replacement

نویسندگان

  • Cheng Zheng
  • Wei-Qian Lin
  • Yuan-Zheng Lin
  • Hao Lian
  • Zhi-Rui Liu
  • Jia-Hui Chen
  • Jia-Feng Lin
چکیده

BACKGROUND In patients with triple valve replacement developing third-degree atrioventricular block (AVB), the most appropriate approach for permanent pacemaker implantation remains questionable. CASE PRESENTATION In this case presentation, we first described the approach of implantation of the cardiac resynchronization therapy pacemaker (CRT-P) via one bipolar pacing lead in middle cardiac vein (MCV) and one quadripolar pacing lead in anterior interventricular vein (AIV) in a patient developing complete AVB, who had been previously diagnosed with rheumatic valvular heart disease with triple valve replaced. After the CRT-P implantation, the two pacing leads in coronary sinus (CS) provided a dual-site ventricular pacing from the anterior septum and posterior septum, which resulted in a narrow QRS complex and an increased ventricular synchrony. During the long-term follow-up, no deterioration of heart function was documented and pacing parameters remained good. CONCLUSION In this patient developing complete AVB with triple valve replaced, our approach of CRT-P implantation provides an effective and reliable ventricular pacing, and is an alternative option when transvenous right ventricular pacing, transseptal left ventricular pacing and transpericardial epicardium pacing are not possible. Further prospective randomized trials are required to confirm the efficiency of our approach of dual-site ventricular pacing by CRT-P in this kind patients.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Implanting CRT via Endo-Cardiac Route When Tricuspid Valve is Metallic

Prosthetic tricuspid valve is an obstacle to implant cardiac devise. Cardiac Resynchronization therapy is one of the most popular therapies for heart failure patients these days. We present this case of prosthetic tricuspid valve and left ventricular dysfunction which we overcome the problem by implanting two leads to coronary sinus branches. Patient improved in few months of follow up.

متن کامل

Feasibility of cardiac resynchronization therapy in a patient with complex congenital heart disease and dextrocardia, facilitated by cardiac computed tomography and coronary sinus venography.

We describe a case with pacemaker implantation for cardiac resynchronization therapy (CRT) in a patient with complex congenital heart disease, facilitated by cardiac computed tomography (CT) and coronary sinus (CS) venography. A 37-year-old male presented with congenitally corrected transposition of the great arteries and mesocardia, along with a history of two open heart surgeries (closure of ...

متن کامل

A 128-slice CT scanner helpful in localising coronary sinus ostium during CRT-D implantation – case report

BACKGROUND Cardiac resynchronization therapy (CRT) has become a successful treatment option for symptomatic heart failure in patients with poor left ventricular (LV) systolic function and broad QRS complex in the surface electrocardiogram (ECG). CASE REPORT In this report we present a case of a 70-year-old woman with advanced heart failure due to ischaemic heart disease who underwent an upgra...

متن کامل

Snare system for left ventricular lead placement in cardiac resynchronization therapy.

A 79-year-old man, previously diagnosed with ischemic heart disease and valve disease, who had undergone coronary artery bypass grafting and aortic valve replacement, was referred for implantation of a cardiac resynchronization system with defibrillator (CRT-D). He was in NYHA functional class III under optimized medical therapy, with left ventricular ejection fraction of 25%, mean QRS of 160 m...

متن کامل

Thoracoscopic Left Ventricular Lead Implantation in Cardiac Resynchronization Therapy

Cardiac resynchronization therapy is known to reduce morbidity and mortality in patients with advanced heart failure as a result of dyssynchrony and systolic dysfunction of the left ventricle. Placement of the left ventricular (LV) lead via the coronary sinus can be difficult. When LV lead implantation is difficult, a video-assisted epicardial approach can be a good alternative. Although there ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 18  شماره 

صفحات  -

تاریخ انتشار 2018