Measurement Technique Using a Fabry-Perot Cavity

نویسندگان

  • Thomas Feuchter
  • Carsten Thirstrup
چکیده

A high precision measurement technique for characterizing the propagation loss in silica low-loss optical waveguides, based on measuring the contrast of a Fabry-Perot cavity, is demonstrated. The cavity consists of the waveguide coupled to two polarization-maintaining fibers, each end facet coated with dielectric mirrors, leaving the reflectivity as an adjustable parameter. The contrast is measured by modulating the cavity length without influence on the waveguide characteristics and the coupling efficiency. A double modulation of the cavity length reduces the measurement uncertainty, and provides a measurement PM-Fiber P Half-Wave Plate _ _ _ _ Polarizer Hi hvokage HI hvoltage Gum %me precision better than 0.1 dB, corresponding to 0.02 dB/cm in case of a 5 cm long waveguide. Laser Diode

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optical vernier technique for in-situ measurement of the length of long Fabry-Perot cavities

We propose a method for in-situ measurement of the length of kilometer size Fabry-Perot cavities in laser gravitational wave detectors. The method is based on the vernier, which occurs naturally when the laser incident on the cavity has a sideband. By changing the length of the cavity over several wavelengths we obtain a set of carrier resonances alternating with sideband resonances. From the m...

متن کامل

Laser Interferometer Gravitational Wave Observatory

We propose a method for in situ measurement of the length of kilometer size Fabry-Perot cavities in laser gravitational wave detectors. The method is based on the vernier, which occurs naturally when the laser incident on the cavity has a sideband. By changing the length of the cavity over several wavelengths we obtain a set of carrier resonances alternating with sideband resonances. From the m...

متن کامل

A novel algorithm for the signal interpolation of the displacement measurement based on a Fabry-Perot interferometer

Current commercial interferometers reveal excellent measurement performances, because of its major advantage which enables the displacement measurement with the characterization of the high resolution under the large measuring range. FabryPerot interferometer is a compact interferometer with the structure of common optical path. In comparison with the ordinary commercial laser interferometers h...

متن کامل

Design, simulation and Fabrication of Circularly Polarized Fabry-Perot Antenna for Ku Band

This paper deals with the design and simulation of a RHCP Fabry-Perot antenna for 14.5 GHz. Based on transmission line model, partially Reflecting Surface (PRS) was designed so thatgain enhancement and circular polarization simultaneously obtained. PRS consist of a square loop and meander-line at the top and bottom respectively. In order to achieve the resonance condition in orthogonal componen...

متن کامل

Design of Optical Fiber Fabry-Perot Sensors Based on Intensity and Phase with Parallel Processing

For fiber Fabry-Perot sensor vulnerable to external parameters such as electromagnetic, noise and displacement impact, reducing the problem resilience, research and design new fiber Fabry-Perot sensor with parallel processing capabilities based on the intensity and phase of perception. First, according to various types of external parameters and the degree of interference, established the inten...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017