Application of the BacT/ALERTR 3D system for sterility testing of injectable products

نویسندگان

  • Adriana Bugno
  • Rodolfo Santos Lira
  • Wesley Anderson Oliveira
  • Adriana Aparecida Buzzo Almodovar
  • Deborah Pita Sanches Saes
  • Terezinha de Jesus Andreoli Pinto
چکیده

Sterility testing as described in the pharmacopoeia compendia requires a 14-day incubation period to obtain an analytical result. Alternative methods that could be applied to evaluating product sterility are especially interesting due to the possibility of reducing this incubation period and thus the associated costs. The aims of this study were to evaluate the performance of the BacT/ALERT(R) 3D system in detecting microorganisms in large-volume parenteral solutions that were intentionally contaminated and to compare this system to pharmacopoeia sterility testing using the membrane filtration method. The results indicated that there were no significant differences between the methods regarding the ability to detect microbial contamination; however, detection with the BacT/ALERT(R) 3D system was faster compared to the pharmacopoeia method. Therefore, the BacT/ALERT(R) 3D system is a viable alternative for assessing the sterility of injectable products.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of the BacT/alert system for rapid detection of microbial contamination in a pilot study using pancreatic islet cell products.

At the Islet Isolation Laboratory of the Scottish National Blood Transfusion Service, manual sterility testing data show that contamination rates are 57.7% for pancreas transport fluid, 4.3% for postpurification islet samples, and 0% for pretransplant islet samples. This pilot study presents the BacT/Alert System as an alternative to manual testing to provide more rapid and sensitive sterility ...

متن کامل

2 3 4 Use of the BacT / ALERT ® System for Rapid Detection of Microbial 5 Contamination in a Pilot Study using Pancreatic Islet

1 Short Form Paper 2 3 4 Use of the BacT/ALERT® System for Rapid Detection of Microbial 5 Contamination in a Pilot Study using Pancreatic Islet Cell Products 6 7 Running Title: BacT/ALERT® System for Islet Cell Sterility Testing 8 9 Laura Murray1, Neil McGowan2, John Fleming1 and Laura Bailey2,3* 10 11 1 Donation Testing Department, Scottish National Blood Transfusion Service, 25 Shelley Road, ...

متن کامل

Performance of the BacT Alert 3D System Versus Solid Media for Recovery and Drug Susceptibility Testing of Mycobacterium tuberculosis in a Tertiary Hospital in Korea

BACKGROUND Tuberculosis (TB) is a major health problem, and accurate and rapid diagnosis of multidrug-resistant (MDR) and extended drug-resistant (XDR) TB is important for appropriate treatment. In this study, performances of solid and liquid culture methods were compared with respect to MDR- and XDR-TB isolate recovery and drug susceptibility testing. METHODS Sputum specimens from 304 patien...

متن کامل

Sterility Testing of Stem Cell Products by Broad-Range Bacterial 16S Ribosomal DNA Polymerase Chain Reaction.

OBJECTIVE To evaluate broad-range 16S ribosomal DNA (rDNA) polymerase chain reaction (PCR) as a rapid screening tool to detect bacterial contamination of stem-cell products. METHODS We performed the evaluation using whole blood spiked with serially diluted bacterial-type strains. Detection sensitivity was defined as the bacterial concentration for which all replicates were positive at each co...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 46  شماره 

صفحات  -

تاریخ انتشار 2015