A kinematics and kinetic comparison of overground and treadmill running.

نویسندگان

  • Patrick O Riley
  • Jay Dicharry
  • Jason Franz
  • Ugo Della Croce
  • Robert P Wilder
  • D Casey Kerrigan
چکیده

PURPOSE The purpose of this study was to compare the kinematic and kinetic parameters of treadmill running to those of overground running. METHODS Twenty healthy young subjects ran overground at their self-selected moderate running speed. Motion capture and ground reaction force (GRF) data for three strides of each limb were recorded and the subjects' average running speed was evaluated. The subjects then ran on an instrumented treadmill set to their average overground running speed while motion capture and GRF data were recorded. The kinematics (body segment orientations and joint angles) and kinetics (net joint moments and joint powers) for treadmill (15 consecutive gait cycles) and overground running (three cycles each limb) were calculated and compared. RESULTS The features of the kinematic and kinetic trajectories of treadmill gait were similar to those of overground gait. Statistically significant differences in knee kinematics,the peak values of GRF, joint moment, and joint power trajectories were identified. DISCUSSION Parameters measured with an adequate instrumented treadmill are comparable to but not directly equivalent to those measured for overground running. With such an instrument, it is possible to study the mechanics of running under well-controlled and reproducible conditions. SIGNIFICANCE Treadmill-based analysis of running mechanics can be generalized to overground running mechanics, provided the treadmill surface is sufficiently stiff and belt speed is adequately regulated.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of lower extremity kinematic curves during overground and treadmill running.

Researchers conduct gait analyses utilizing both overground and treadmill modes of running. Previous studies comparing these modes analyzed discrete variables. Recently, techniques involving quantitative pattern analysis have assessed kinematic curve similarity in gait. Therefore, the purpose of this study was to compare hip, knee and rearfoot 3-D kinematics between overground and treadmill run...

متن کامل

Methods for Quantifying the Variability in Time-series Data

Using a treadmill to monitor locomotion is extremely convenient for sport and exercise research (Nigg et al., 1995). A problem exists if kinematic, kinetic, and metabolic or other variables, for example, are not uniform between treadmill and overground locomotion. As Nigg et al. (1995) suggested discussion about the degree of similarity between overground and treadmill running is inconsistent t...

متن کامل

Comparing the Effects of Fatigue Caused by the Treadmill and Overground Running on the Pattern of Plantar Pressure Distribution

Purpose: This study aimed to compare the effects of fatigue due to overground and treadmill running on the plantar pressure distribution pattern.  Methods: Twelve novice athletes (Mean±SD age=26.0±2.5 y, Mean±SD weight: 52.0±3.0 kg, Mean±SD height: 159.0±5.0 cm), without sports injuries over the past year, were selected. Overground and treadmill running created fatigue in the samples. Peak pla...

متن کامل

Joint kinematics and kinetics of overground accelerated running versus running on an accelerated treadmill.

Literature shows that running on an accelerated motorized treadmill is mechanically different from accelerated running overground. Overground, the subject has to enlarge the net anterior-posterior force impulse proportional to acceleration in order to overcome linear whole body inertia, whereas on a treadmill, this force impulse remains zero, regardless of belt acceleration. Therefore, it can b...

متن کامل

A comparison of three-dimensional breast displacement and breast comfort during overground and treadmill running.

Comparisons of breast support requirements during overground and treadmill running have yet to be explored. The purpose of this study was to investigate 3D breast displacement and breast comfort during overground and treadmill running. Six female D cup participants had retro-reflective markers placed on the nipples, anterior superior iliac spines and clavicles. Five ProReflex infrared cameras (...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medicine and science in sports and exercise

دوره 40 6  شماره 

صفحات  -

تاریخ انتشار 2008