A multi-syringe flow injection system for the spectrophotometric determination of trace levels of iron in waters using a liquid waveguide capillary cell and different chelating resins and reaction chemistries

نویسندگان

  • Ricardo N.M.J. Páscoa
  • Ildikó V. Tóth
  • António O.S.S. Rangel
چکیده

A method integrating a long waveguide capillary cell with a preconcentration resin in a multi-syringe flow injection analysis (MSFIA) system for iron determination in waters was developed. The determination of iron is based on a colorimetric reaction and two reagents were tested, ferrozine and ammonium thiocyanate. A liquid waveguide capillary cell (1.0 m pathlength, 550 μm i.d. and 250 μL internal volume) with a preconcentration resin were used to improve the sensitivity of the determination. Two different preconcentration resins were also tested, Chelex 100 and NTA Superflow. The developed method employing the NTA Superflow with ferrozine colorimetric reagent provided a detection limit of 0.05 μg L−1 with a linear response up to 8 μg L−1 and a sample throughput rate of 12 per hour. The developed system presents low ⁎ Corresponding author. Tel.: +351 225580064; fax: + E-mail address: [email protected] (A.O.S.S. Rangel s assessed using a certified reference water sample. reagents/sample consumptions. The accuracy wa

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spectrophotometric determination of zinc and copper in a multi-syringe flow injection analysis system using a liquid waveguide capillary cell: application to natural waters.

This work exploits a multi-syringe injection analysis (MSFIA) system coupled with a long liquid waveguide capillary cell for the spectrophotometric determination of zinc and copper in waters. A liquid waveguide capillary cell (1.0m pathlength, 550 μm i.d. and 250 μL internal volume) was used to enhance the sensitivity of the detection. The determination for both ions is based on a colorimetric ...

متن کامل

Sequential injection trace determination of iron in natural waters using a long-pathlength liquid core waveguide and different spectrophotometric chemistries

We developed a sequential injection analysis (SIA) method for the determination of iron in coastal, ground, and surface fresh waters using two different reagents (ferrozine and 1,10-phenathroline). The methodology uses a double-line SIA system to improve mixing conditions between sample and reagent solutions. A liquid waveguide capillary cell (LWCC) with 1.0 m pathlength, 550 μm i.d., and 250 μ...

متن کامل

Enhanced sensitivity in flow injection analysis using a long pathlength liquid waveguide capillary flow cell for spectrophotometric detection.

Incorporation of a liquid waveguide capillary flow cell into a flow injection instrument enhances the sensitivity of flow injection analysis with spectrophotometric detection by two orders of magnitude. Nitrite determination at nM levels has been used to demonstrate the feasibility of this novel technique for trace analysis. Combining the long pathlength spectrophotometry with flow injection an...

متن کامل

Ultra-trace Determination of Palladium(II) by Spectrophotometric Flow Injection Analysis

Nowadays, palladium compounds due to their especial characteristics used in different industries, mainly in electrical power sources and chemical productions as a catalyst. Therefore, Pd concentration is increasing in our around that can be contaminant our environment due its toxic effects. In this work, a simple, selective and rapid flow injection method of analysis (FIA) has been developed fo...

متن کامل

Rapid speciation of trace iron in rainwater by reverse flow injection analysis coupled to a long path length liquid waveguide capillary cell and spectrophotometric detection

A method for speciation and determination of low levels of dissolved iron in rainwater was established by coupling reverse flow injection analysis with a 2-m liquid waveguide capillary cell and spectrophotometric detection. Ferrozine solution was injected into a sample stream to form an Fe(II)-ferrozine complex with Fe(II), and the absorbance of this complex was detected at both 562 nm and 625 ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009