Incidental Saccular Aneurysms on Head MR Angiography: 5 Years' Experience at a Single Large-Volume Center
نویسندگان
چکیده
BACKGROUND AND PURPOSE The diagnostic accuracy for unruptured intracranial aneurysms has increased, and incidental asymptomatic aneurysms have come to represent a substantial clinical burden because of their controversial natural history. However, their prevalence may be attributable to variations in evaluation methods and demographics. We therefore describe the prevalence and magnetic resonance angiography (MRA) findings of incidental intracranial saccular aneurysms over a 5-year period at a single large-volume center. METHODS MRA images from 18,237 patients obtained between January 2001 and December 2005 were retrieved from the radiology report database. Patients diagnosed with incidental intracranial saccular aneurysms were identified and their MRA data were reviewed. Imaging and clinical follow-up data were evaluated. RESULTS During the study period, 366 incidental intracranial saccular aneurysms were identified in 330 patients (prevalence, 1.8%; 95% confidence interval, 1.63%-2.01%; 115 men and 215 women; age range, 22-82 years; median age, 63 years). The prevalence was higher in women (215/8,112) than in men (115/10,125; P=0.02). The prevalence increased with age in women (P<0.01), but not in men (P=0.30). Aneurysm size ranged from 1.5 mm to 13 mm, with a median size of 4 mm. The most common location was the bifurcation of the middle cerebral artery (131/366; 35.8%). CONCLUSIONS Our real world experience indicated a slightly lower overall prevalence of incidental intracranial saccular aneurysms than previously reported. The prevalence increased with age in women but not in men.
منابع مشابه
MR angiography of aneurysm models of various shapes and neck sizes.
PURPOSE To investigate the signal intensity of lateral and terminal saccular aneurysm models with differing neck sizes using three-dimensional time-of-flight (TOF) MR angiography with various imaging parameters. METHODS The study included four lateral and four terminal saccular aneurysm models with pulsatile flow. The height and fundus diameter were 10 mm; the neck diameters were 2.5 mm, 5 mm...
متن کاملCerebral Angiographic Findings in Non-Traumatic Intracranial Hemorrhage: A Single Center Experience in the West of Iran
Background and Aim: This study aimed at analyzing the demographic characteristics of the patients with non-traumatic intracranial hemorrhage, their angiographic results and the correlation between computed tomography (CT) scan and angiography findings. Methods and Materials/Patients: In a descriptive study, we retrospectively reviewed the records of the patients with non-traumatic intracranial...
متن کاملDiagnosis of intracranial aneurysms: accuracy of MR angiography at 0.5 T.
PURPOSE Our goal was to determine the accuracy of MR angiography at 0.5 T for the diagnosis of intracranial aneurysms. METHODS We retrospectively studied 140 patients, 70 with acute subarachnoid hemorrhage, who were either at high or low risk for intracranial aneurysm. Three-dimensional time-of-flight MR angiography was typically performed to cover the circle of Willis, with a volume thicknes...
متن کاملRoutine cerebral angiography after surgery for saccular aneurysms: is it worth it?
OBJECTIVE The objective of this study was to determine whether an angiographically proven rate of saccular intracranial aneurysm occlusion after surgical clipping suggests that postoperative angiography should continue to be used routinely or should be supplanted by intraoperative angiography. These data also should establish a basis for comparing surgery with new endovascular methods of treatm...
متن کاملThe next generation HydroCoil: initial clinical experience with the HydroFill embolic coil
BACKGROUND Complete packing of intracranial aneurysms has demonstrated a significant decrease in aneurysm recurrence rates with increased volumetric filling. The HydroCoil Embolization System (HES) was developed to increase volumetric filling within the aneurysm sac to maintain long term occlusion. To further enhance ease of HES deployment, a new next generation embolic coil, the HydroFill coil...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 16 شماره
صفحات -
تاریخ انتشار 2014