System for dynamic measurements of membrane capacitance in intact epithelial monolayers.

نویسندگان

  • C A Bertrand
  • D M Durand
  • G M Saidel
  • C Laboisse
  • U Hopfer
چکیده

Dynamic measurements of exocytosis have been difficult to perform in intact epithelial monolayers. We have designed a system that estimates with +/-1% accuracy (99% confidence) the total membrane capacitance of monolayers represented by a lumped model. This impedance measurement and analysis system operates through a conventional transepithelial electrophysiology clamp, performing all signal measurements as frequently as every 5 s. Total membrane capacitance (the series combination of apical and basolateral membranes) is the inverse of one of three unique coefficients that describe the monolayer impedance. These coefficients are estimated using a weighted, nonlinear, least-squares algorithm. Using the estimated coefficients, solution ranges for individual membrane parameters are calculated, frequently providing results within +/-20% of true values without additional electrophysiological measurements. We determined the measurement system specifications and statistical significance of estimated parameters using 1) analytical testing with circuit simulation software and equation-generated data; 2) a system noise analysis combined with Monte Carlo simulations; and 3) analog model circuits for calibration of the electronic system and to check equation-generated results. Finally, the time course of capacitance changes associated with purinergically stimulated mucin exocytosis are quantified in monolayers of the colonic goblet cell-like cell line HT29-CI.16E.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

APPENDIX A: Ambiguities observed with spontaneous FM 1-43 labeling in epithelial cells

Several labs have measured the spontaneous and stimulated increases in FM 1-43 fluorescence combined with simultaneous capacitance measurements to confirm the method’s viability (1-4). In these tests, the capacitance of single cells was measured using whole-cell patch clamping. By design, the corresponding fluorescence changes were also measured on single cells, either by monitoring changes in ...

متن کامل

Effect of LH Treated Ovine Oviductal Epithelial Cell Co-Culture System on Murine Pre-Embryo Development

Background This study was designed to develop a new co-culture system, assess the effect of luteinizing hormone (LH) using sequential media to promote development and increase the quality of 2-cell murine embryos through the 8-16 cell stage to morula and blastocyst stages. MaterialsAndMethods Monolayers for co-culture were prepared from ovine oviduct epithelial cells (OOEC) in DMEM/F12 medium a...

متن کامل

Purinergic and cholinergic agonists induce exocytosis from the same granule pool in HT29-Cl.16E monolayers.

Several secretagogues induce mucin secretion in epithelial monolayers, as determined by measuring released granule contents. To assess whether different agonists act on the same granule pool, capacitance changes in intact monolayers of the goblet cell line HT29-Cl.16E were measured by a novel impedance method. Apical ATP (purinergic agonist) and basolateral carbachol (cholinergic agonist) induc...

متن کامل

Epithelial monolayer culture system for real‐time single‐cell analyses

Abstract Many epithelial cells form polarized monolayers under in vivo and in vitro conditions. Typically, epithelial cells are cultured for differentiation on insert systems where cells are plated on a porous filter membrane. Although the cultured monolayers have been a standard system to study epithelial physiology, there are some limits: The epithelial cells growing inside the commercial ins...

متن کامل

Capacitance measurements in the mouse rod bipolar cell identify a pool of releasable synaptic vesicles.

The mouse is an important model system for understanding the molecular basis of neuronal signaling and diseases of synaptic communication. However, the best-characterized retinal ribbon-style synapses are those of nonmammalian vertebrates. To remedy this situation, we asked whether it would be feasible to track synaptic vesicle dynamics in the isolated mouse rod bipolar cell using time-resolved...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Biophysical journal

دوره 75 6  شماره 

صفحات  -