Effects of Calibration Approaches on the Accuracy for LC–MS Targeted Quantification of Therapeutic Protein
نویسندگان
چکیده
LC-MS provides a promising alternative to ligand-binding assays for quantification of therapeutic proteins and biomarkers. As LC-MS methodology is based on the analysis of proteolytic peptides, calibration approaches utilizing various calibrators and internal standards (I.S.) have been developed. A comprehensive assessment of the accuracy and reliability of these approaches is essential but has yet been reported. Here we performed a well-controlled and systematic comparative study using quantification of monoclonal-antibody in plasma as the model system. Method development utilized a high-throughput orthogonal-array-optimization, and two sensitive and stable signature-peptides (SP) from different domains were selected based on extensive evaluations in plasma matrix. With the purities of all protein/peptide standards corrected by quantitative amino acid analysis (AAA), five calibration approaches using stable-isotope-labeled (SIL) I.S. were thoroughly compared, including those at peptide, extended-peptide, and protein levels and two "hybrid" approaches (i.e., protein calibrator with SIL-peptide or SIL-extended-peptide I.S.). These approaches were further evaluated in parallel for a 15 time point, preclinical pharmacokinetic study. All methods showed good precision (CV% < 20%). When examined with protein-spiked plasma QC, peptide-level calibration exhibited severe negative biases (-23 to -62%), highly discordant results between the two SP (deviations of 38-56%), and misleading pharmacokinetics assessments. Extended-peptide calibration showed significant improvements but still with unacceptable accuracy. Conversely, protein-level and the two hybrid calibrations achieved good quantitative accuracy (error < 10%), concordant results by two SP (deviations < 15%), and correct pharmacokinetic parameters. Hybrid approaches were found to provide a cost-effective means for accurate quantification without the costly SIL-protein. Other key findings include (i) using two SP provides a versatile gauge for method reliability; (ii) evaluation of peptide stability in the matrix before SP selection is critical; and (iii) using AAA to verify purities of protein/peptide calibrators ensures accurate quantitation. These results address fundamental calibration issues that have not been adequately investigated in published studies and will provide valuable guidelines for the "fit for purpose" development of accurate LC-MS assays for therapeutic proteins and biomarkers in biological matrices.
منابع مشابه
Liquid chromatography–tandem mass spectrometry (LC-MS) method for the assignment of enalapril and enalaprilat in human plasma
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method was developed for the determination of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode which was operated under the multiple-reaction monitoring mode. Sample pretreatment was involved...
متن کاملQuantification of Melittin in Iranian Honey Bee (Apis mellifera meda) Venom by Liquid Chromatography-electrospray Ionization-ion Trap Tandem Mass Spectrometry (LC-ESI-IT-MS/MS)
The current research aimed to quantify melittin (MEL) in Iranian honey bee (Apis mellifera meda) venom. To this end, a liquid chromatography-electrospray ionization-ion trap tandem mass spectrometry (LC-ESI-IT-MS/MS) approach was employed. Melittin is the main toxic peptide of honey bee venom with various biological and pharmacological activities. It was extracted with...
متن کاملTarget analyte quantification by isotope dilution LC-MS/MS directly referring to internal standard concentrations--validation for serum cortisol measurement.
BACKGROUND Isotope dilution LC-MS/MS methods used in the clinical laboratory typically involve multi-point external calibration in each analytical series. Our aim was to test the hypothesis that determination of target analyte concentrations directly derived from the relation of the target analyte peak area to the peak area of a corresponding stable isotope labelled internal standard compound [...
متن کاملA quick and Sensitive Liquid Chromatography–tandem Mass Spectrometry (LC-MS) Method for the Determination of Enalapril and Enalaprilat in Human Plasma: Application to a Bioequivalence Study
A rapid and sensitive liquid chromatography–tandem mass spectrometry (LC-MS) method for the estimation of enalapril and enalaprilat in human plasma. Detection of analytes was achieved by tandem mass spectrometry with electrospray ionization (ESI) interface in positive ion mode was operated under the multiple-reaction monitoring mode. Sample pretreatment involved in a one-step protein precipitat...
متن کاملComparison of extraction and quantification methods of perfluorinated compounds in human plasma, serum, and whole blood.
Perfluorinated compounds are ubiquitous in the environment and have been reported to occur in human blood. Accurate risk assessments require accurate measurements of exposures, but identification and quantification of PFCs in biological matrices can be affected by both ion suppression and enhancement in liquid chromatography-tandem mass spectrometry techniques (LC/MS-MS). A study was conducted ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 86 شماره
صفحات -
تاریخ انتشار 2014