Differential tissue shrinkage and compression in the z-axis: implications for optical disector counting in vibratome-, plastic- and cryosections.
نویسندگان
چکیده
The optical disector is among the most efficient cell counting methods, but its accuracy depends on an undistorted particle distribution in the z-axis of tissue sections. Because the optical disector samples particle densities exclusively in the center of sections, it is essential for unbiased estimates of particle numbers that differential shrinkage or compression (and resulting differences in particle densities along the z-axis) are known and corrected. Here we examined, quantified, and compared differential shrinkage and compression of vibratome-, celloidin- and cryosections. Vibratome sections showed a significant z-axis distortion, while celloidin- and cryosections were minimally distorted. Results were directly compared with previous data obtained from paraffin and methacrylate sections. We conclude that z-axis distortion varies significantly between embedding and sectioning methods, and that vibratome-, methacrylate- and paraffin sections can result in grossly biased estimates. We describe a simple method for assessing differential z-axis shrinkage or compression, as well as simple strategies to minimize the bias of the optical disector. Minimal bias can be achieved by either adjusting the placement and extent of counting boxes and guard spaces for sampling, or by applying a correction factor in cases when guard spaces are deemed essential for particle recognition.
منابع مشابه
Is frozen sections an advantage for unbiased stereological methods ?
References [1] West MJ. New stereological methods for counting neurons. Analysis of cell death in the trochlear nucleus of the chick embryo: calibration of the optical dissector counting method reveals systematic bias. Differential tissue shrinkage and compression in the z-axis: implications for optical dissector counting in vibratome, plastic and cryosections. Use of cryostat sections from sna...
متن کاملQuantitative stereology: the use of camera lucida for counting neurons by physical dissector method in chick brainstem auditory nuclei.
Subtle changes in neuron numbers during growth and ageing as well as consequent to manipulation, nutritional and environmental influences and following drug or toxin intake are best assessed quantitatively. The disector introduced in 1984 by Sterio is an unbiased, systematically randomised method for neuronal counting applied as an optical or physical method. The optical disector requires a con...
متن کاملQuantitative caveats of standard immunohistochemical procedures: implications for optical disector-based designs.
Immunohistochemistry is a ubiquitous technique in histology. Often, the goal of such studies is the quantification of some parameter associated with a particular antigen. When used correctly, the optical disector offers a statistically relevant approach to achieve this goal without bias from cell size, shape, or orientation. This three-dimensional counting probe is virtually embedded within the...
متن کاملElastic/plastic Buckling Analysis of Skew Thin Plates based on Incremental and Deformation Theories of Plasticity using Generalized Differential Quadrature Method
Abstract In this study, generalized differential quadrature analysis of elastic/plastic buckling of skew thin plates is presented. The governing equations are derived for the first time based on the incremental and deformation theories of plasticity and classical plate theory (CPT). The elastic/plastic behavior of plates is described by the Ramberg-Osgood model. The ranges of plate geometries...
متن کاملPost-Operative Time Effects after Sciatic Nerve Crush on the Number of Alpha Motoneurons, Using a Sterological Counting Method (Disector)
There are extensive evidences that show axonal processes of the nervous system (peripheral and/or central) may be degenerated after nerve injuries. Wallerian degeneration and chromatolysis are the most conspicuous phenomena that occur in response to injuries. In this research, the effects of post-operative time following sciatic nerve crush on the number of spinal motoneurons were investigated....
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of neuroscience methods
دوره 124 1 شماره
صفحات -
تاریخ انتشار 2003