Optimization of the matrix inversion tomosynthesis (MITS) impulse response and modulation transfer function characteristics for chest imaging.

نویسندگان

  • Devon J Godfrey
  • H P McAdams
  • James T Dobbins
چکیده

Matrix inversion tomosynthesis (MITS) uses linear systems theory, along with a priori knowledge of the imaging geometry, to deterministically distinguish between true structure and overlying tomographic blur in a set of conventional tomosynthesis planes. In this paper we examine the effect of total scan angle (ANG), number of input projections (N), and plane separation/number of reconstructed planes (NP) on the MITS impulse response (IR) and modulation transfer function (MTF), with the purpose of optimizing MITS imaging of the chest. MITS IR and MTF data were generated by simulating the imaging of a very thin wire, using various combinations of ANG, N, and NP. Actual tomosynthesis data of an anthropomorphic chest phantom were acquired with a prototype experimental system, using the same imaging parameter combinations as those in the simulations. Thoracic projection data from two human subjects were collected for corroboration of the system response analysis in vivo. Results suggest that ANG=20 degrees, N=71, NP=69 is the optimal combination for MITS chest imaging given the inherent constraints of our prototype system. MITS chest data from human subjects demonstrates that the selected imaging strategy can effectively produce high-quality MITS thoracic images in vivo.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Impulse response analysis for several digital tomosynthesis mammography reconstruction algorithms

ABSTRACT Digital tomosynthesis mammography algorithms allow reconstructions of arbitrary planes in the breast from limitedangle series of projection images as the x-ray source moves along an arc above the breast. Though several tomosynthesis algorithms have been proposed, no complete comparison of the methods has previously been conducted. This paper presents an analysis of impulse response for...

متن کامل

Gaussian frequency blending algorithm with Matrix Inversion Tomosynthesis (MITS) and Filtered Back Projection (FBP) for better digital breast tomosynthesis reconstruction

Breast cancer is a major problem and the most common cancer among women. The nature of conventional mammography makes it very difficult to distinguish a cancer from overlying breast tissues. Digital Tomosynthesis refers to a three-dimensional imaging technique that allows reconstruction of an arbitrary set of planes in the breast from limited-angle series of projection images as the x-ray sourc...

متن کامل

Methodology of NEQ (f) analysis for optimization and comparison of digital breast tomosynthesis acquisition techniques and reconstruction algorithms

As a new three-dimensional imaging technique, digital breast tomosynthesis allows the reconstruction of an arbitrary set of planes in the breast from a limited-angle series of projection images. Though several tomosynthesis algorithms have been proposed, no complete optimization and comparison of different tomosynthesis acquisition techniques for available methods has been conducted as of yet. ...

متن کامل

Digital tomosynthesis of hand joints for arthritis assessment.

The two principal forms of hand arthritis, rheumatoid arthritis (RA) and osteoarthritis (OA) have large clinical and economic costs. Radiography has been shown to be a useful tool to assess the condition of the disease. A hand radiograph, however, is a two-dimensional projection of a three-dimensional object. In this report we present the results of a study that applied digital tomosynthesis to...

متن کامل

Breast tomosynthesis reconstruction with a multi-beam x-ray source

As a new three-dimensional breast imaging technique, breast tomosynthesis allows the reconstruction of an arbitrary set of planes in the breast from a limited-angle series of x-ray projection images. The breast tomosynthesis technique has been demonstrated as promising to improve early breast cancer detection. This paper represents a preliminary phantom study and computer simulation results of ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 33 3  شماره 

صفحات  -

تاریخ انتشار 2006