1.2 CMOS Single-chip Gas Detection Systems: Part II
نویسندگان
چکیده
Sensor arrays based on industrial CMOS-technology combined with post-CMOS micromachining (CMOS MEMS) are a promising approach to low-cost sensors. In the first part of this article [1], the state of research on CMOS-based gas sensor systems was reviewed, and a platform technology for monolithic integration of three different transducers on a single chip was described. In this second part, the transduction principles of three polymer-based gas sensors are detailed and the read-out circuitry is portrayed. The first transducer is a micromachined resonant cantilever. The absorption of analyte in the chemically sensitive polymer causes shifts in resonance frequency as a consequence of changes in the oscillating mass. The cantilever acts as the frequency-determining element in an oscillator circuit, and the resulting frequency change is read out by an on-chip counter. The second transducer is a planar capacitor with polymer-coated interdigitated electrodes. This transducer monitors changes in the dielectric constant upon absorption of the analyte into the polymer matrix. The sensor response is read out as a differential signal between the coated sensing capacitor and a passivated reference capacitor, both of which are incorporated into the input stage of a switched capacitor second-order -modulator. The third transducer is a thermoelectric calorimeter, which detects enthalpy changes upon ab-/desorption of analyte molecules into a polymer film located on a thermally insulated membrane. The enthalpy changes in the polymer film cause transient temperature variations, which are detected via polysilicon/aluminum thermocouples (Seebeck effect). The small signals in the Vrange are first amplified with a low-noise chopper amplifier, then converted to a digital signal using a -A/D-converter and finally decimated and filtered with a digital decimation filter.
منابع مشابه
Ultra-High Sensitivity Zinc Oxide Nanocombs for On-Chip Room Temperature Carbon Monoxide Sensing
In this paper, we report an on-chip gas sensor based on novel zinc oxide (ZnO) nanocombs for carbon monoxide (CO) sensing. With ZnO gas sensing nanocombs fully integrated on a single silicon chip, the concept of low cost complementary-metal-oxide-semiconductor (CMOS) microsensor capable of on-chip gas sensing and processing is enabled. Compared with all previous implementations, the proposed Zn...
متن کاملA Single-Chip CMOS Pulse Oximeter with On-Chip Lock-In Detection
Pulse oximetry is a noninvasive and continuous method for monitoring the blood oxygen saturation level. This paper presents the design and testing of a single-chip pulse oximeter fabricated in a 0.35 µm CMOS process. The chip includes photodiode, transimpedance amplifier, analogue band-pass filters, analogue-to-digital converters, digital signal processor and LED timing control. The experimenta...
متن کاملDesign of High Speed, Low Power and Wide range Ripple Detector for On-Chip testing in CMOS Technology
On chip testing is an attractive solution for testing of analog integrated circuits. In this paper a low power , built in CMOS Ripple Detector is presented for the purpose of detecting the ripples in the supply rails and specifies its application for On chip testing. The detector works on the principle of RMS detection. The circuit outputs a DC signal that is proportional to the peak to peak am...
متن کاملMolecular Detection for Unconcentrated Gas with ppm Sensitivity Using 220-to-320 GHz Dual-Frequency-Comb Spectrometer in CMOS
Millimeter-wave/terahertz rotational spectroscopy of polar gaseous molecules provides a powerful tool for complicated gas mixture analysis. In this paper, a 220-to-320GHz dualfrequency-comb spectrometer in 65-nm bulk CMOS is presented, along with a systematic analysis on fundamental issues of rotational spectrometer, including the impacts of various noise mechanisms, gas cell, molecular propert...
متن کاملThe detection of single electrons by means of a Micromegas-covered MediPix2 pixel CMOS readout circuit
A small drift chamber was read out by means of a MediPix2 readout chip as direct anode. A Micromegas foil was placed 50 μm above the chip, and electron multiplication occurred in the gap. With a He/Isobutane 80/20 mixture, gas multiplication factors up to tens of thousands were achieved, resulting in an efficiency for detecting single electrons of better than 90% . We recorded many frames conta...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -