Placement of a double-lumen tube using LMA C Trach and an exchanger catheter in difficult airway intubation -A case report-
نویسنده
چکیده
During insertion of the double lumen tube in patients with cervical vertebral fixation, the cervical neutral position should be maintained. Although flexible fiberoptic bronchoscopic intubation is the gold standard, novel techniques are needed to facilitate intubation of patients with cervical vertebral fixation in neutral position according to institutional capabilities. In this case report, insertion of the double lumen tube in the neutral position using LMA CTrach and an airway exchanger catheter in a thoracotomy patient with extremely limited head and neck motion due to fixation of the cervical vertebrae is presented.
منابع مشابه
Placement of a double lumen tube in a patient with difficult intubation due to ankylosing spondylitis--a case report.
During insertion of the double lumen tube in patients with ankylosing spondylitis, cervical neutral position should be maintained to avoid vertebral and spinal injuries. Although flexible fiberoptic bronchoscopic intubation is the gold standard, available FOB size is not compatible with that of the endobronchial lumen of the double lumen tube. This problem should be solved according to institut...
متن کاملUse of the Aintree Intubation Catheter with the Laryngeal Mask Airway and a Fiberoptic Bronchoscope in a Patient with an Unexpected Difficult Airway
Purpose: To present a case where the Aintree intubation catheter was used in conjunction with the Laryngeal Mask Airway (LMA) and a fiberoptic bronchoscope (FOB) in a patient with an unexpected difficult airway. Clinical Features: A 38 year old 90 kg man scheduled for nasal endoscopy with ethmoidectomy under general anesthesia was found to be unexpectedly difficult to intubate using a both a MA...
متن کاملUsefulness of a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation in a neonate with Pierre Robin syndrome -A case report-
The case of a 33-day-old boy with Pierre Robin syndrome using a Cook® airway exchange catheter in laryngeal mask airway-guided fiberoptic intubation is presented. After induction with sevoflurane, classical reusable laryngeal mask airway (LMA) #1 was inserted and ultrathin fiberoptic bronchoscope (FOB) was passed through. A Cook® airway exchange catheter (1.6 mm ID, 2.7 mm OD) was passed throug...
متن کاملRetrograde Intubation via Laryngeal Mask Airway in a Paediatric Patient with Fallot-type Ventricular Septal Defect and Cleft Palate Deformity.
We report the case ofa pediatric patient with tetralogy of Fallot (TOF) and cleft palate deformity with difficult intubation in which a laryngeal mask airway (LMA) was used and converted into an endotracheal tube through retrograde intubation. The patient with TOF was scheduled for repair of the congenital bilateral cleft lip and palate. Inhalational induction with 4% sevoflurane was started. C...
متن کاملA clinical trial evaluating the laryngeal mask airway-Supreme in obese children during general anesthesia
INTRODUCTION The laryngeal mask airway (LMA)-Supreme is a disposable double-lumen laryngeal mask airway that is widely used in clinical practice. However, its use in obese children has not been evaluated. The aim of this study was to determine whether the LMA-Supreme could perform equally as well as endotracheal intubation in obese children having a minor surgical procedure. MATERIAL AND METH...