NIST-Sponsored Interlaboratory Comparison of Polystyrene Molecular Mass Distribution Obtained by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry: Statistical Analysis

نویسندگان

  • Charles M. Guttman
  • Stephanie J. Wetzel
  • William R. Blair
  • Bruno M. Fanconi
  • James E. Girard
  • Robert J. Goldschmidt
  • William E. Wallace
  • David L. VanderHart
چکیده

The method of preparation and methods of analysis of a narrow distribution polystyrene of ∼7 ku used in an interlaboratory comparison of matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF-MS) of synthetic polymers is described. Size exclusion chromatography was used to measure the polystyrene sample variability. Fourier transform infrared spectroscopy and MALDI-TOF-MS were used to analyze end groups on the polymer. The polystyrene was analyzed by MALDI-TOF-MS and classical methods of polymer characterization. The number (Mn) and mass (Mw) average of the molecular mass distribution (MMD) determined by the classical methods (light scattering and NMR) were compared with those obtained by MALDI-TOF-MS. Agreement between classical methods to obtain the moments of the MMD and the MALDI is found to be good overall. However, all the experimental values obtained by MALDI fell below the classical values. A discussion of why these values are lower is included. We discuss the statistical analysis of the data from the interlaboratory comparison conducted by NIST, which includes data from 23 different laboratories. Analysis of variance is used to examine the influences of the independent parameters (laboratory, matrix, instrument manufacturer, instrument mode) on the data. The parameters, laboratory and instrument manufacturer, were determined to have an influence on the MMD, where matrix and instrument mode were found not to have a significant influence.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Certification of a Polystyrene Synthetic Polymer, SRM 2888

The certification of a polystyrene standard reference material, SRM 2888, is described. The Mw of SRM 2888 was determined by light scattering to be 7.19x10 g/mol with a sample standard deviation of 0.14 x10 g/mol. A combined expanded uncertainty for this light scattering Mw determination, including systematic and random uncertainties, was estimated to be 0.57 x10 g/mol. Mn was determined by nuc...

متن کامل

Matrix-assisted laser desorption/ionization time-of-flight mass spectrometry interlaboratory comparison of mixtures of polystyrene with different end groups: statistical analysis of mass fractions and mass moments.

A matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOF MS) interlaboratory comparison was conducted on mixtures of synthetic polymers having the same repeat unit and closely matching molecular mass distributions but with different end groups. The interlaboratory comparison was designed to see how well the results from a group of experienced laboratories would ...

متن کامل

Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer

A time-of-flight mass spectrometer (TOF-MS) developed in our laboratory at Isfahan University of Technology is described here. The TOF-MS instrument uses laser as the ionization source which provides an opportunity to investigate the ions formed in laser ablation or desorption. The TOF-MS has an ionization chamber containing an accelerator and an ion lens to focus the ions into a one meter line...

متن کامل

Matrix-assisted ultraviolet laser-desorption ionization time-of-flight mass spectrometry of sulfated mannans from the red seaweed Nothogenia fastigiata.

Matrix-assisted ultraviolet laser-desorption ionization time-of-flight mass spectrometry (UV-MALDI-TOF-MS) was applied to sulfated xylo-mannan fractions from Nothogenia fastigiata in order to determine their molecular weights and distribution profiles. The number-average molecular weight calculated from the spectra was similar to that determined by chemical end-group analysis for the lower mole...

متن کامل

Coupling thermal field-flow fractionation with matrix-assisted laser desorption/ionization time-of-flight mass spectrometry for the analysis of synthetic polymers.

Thermal field-flow fractionation (ThFFF) and matrix-assisted laser desorption/ionization time-of-flight mass spectrometry (MALDI-TOFMS) have been coupled to yield a powerful combination of techniques for polymer analysis. Thermal FFF's high molecular weight (MW) selectivity and sensitivity to chemical composition are used to separate polydisperse polymers and polymer mixtures into the narrow po...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001