Ocular parameters before and after steep Trendelenburg positioning for robotic-assisted laparoscopic radical prostatectomy

نویسندگان

  • Kyoichi Mizumoto
  • Masahiko Gosho
  • Masayoshi Iwaki
  • Masahiro Zako
چکیده

PURPOSE Intraocular pressure (IOP) increases in patients in a steep Trendelenburg position during robotic-assisted laparoscopic radical prostatectomy (RALP). We hypothesized that a steep Trendelenburg position during RALP, an unusual systemic condition involving a transiently increased IOP, may induce ocular pathology that can be detected by detailed evaluations long after the surgery. This study aims to explore ocular structural and functional parameters in patients before and in the long term after the surgery. PATIENTS AND METHODS A comparative observational study was performed. A total of 44 eyes of 22 male patients scheduled for RALP at Aichi Medical University from August 2012 to July 2013 were included. Clinical parameters before and after RALP were compared. Perioperative IOP was measured immediately post-induction of anesthesia in the flat supine position (T1), immediately post-steep Trendelenburg position (T2), and prior to returning to a flat supine position while in a steep Trendelenburg position (T3). The thicknesses of the peripapillary retinal nerve fiber layer, ganglion cell complex (GCC), and central fovea were measured with spectral domain optical coherence tomography. Humphrey perimetry was performed before and at 3 and 6 months after surgery. RESULTS The average IOPs (mmHg) at each stage were T1=10.4, T2=21.7, and T3=29.6, and differed significantly. The mean visual acuity (logarithm of the minimal angle of resolution), IOP, mean deviation, and pattern standard deviation measured by the Humphrey field analyzer showed no statistically significant difference before and after surgery. The ganglion cell complex and retinal nerve fiber layer thicknesses measured at each location and the central fovea thicknesses measured before and after surgery did not differ significantly. CONCLUSION No significant disorders in ocular structural and functional parameters were found until long after RALP.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The effect of steep Trendelenburg positioning on intraocular pressure and visual function during robotic-assisted radical prostatectomy

BACKGROUND To evaluate intraocular pressure (IOP) changes in patients undergoing robotic-assisted radical prostatectomy and to evaluate complications from increased IOP. METHODS Thirty-one eyes scheduled for robotic prostatectomy were included. Perioperative IOP measurements were performed as follows: prior to induction of anaesthesia while supine and awake (T1); immediately post-induction wh...

متن کامل

Sonographic optic nerve sheath diameter as a surrogate measure for intracranial pressure in anesthetized patients in the Trendelenburg position

BACKGROUND It remains to be elucidated whether the Trendelenburg position increases intracranial pressure (ICP). ICP can be evaluated by measuring the sonographic optic nerve sheath diameter (ONSD). We investigated the effect of the isolated Trendelenburg position on ONSD in patients undergoing robot-assisted laparoscopic radical prostatectomy. Additionally, we evaluated the effect of the Trend...

متن کامل

Simplifying patient positioning and port placement during robotic-assisted laparoscopic prostatectomy.

Proper patient positioning and port placement is of critical importance in robotic-assisted laparoscopic radical prostatectomy (RALP). Not having the patient in the correct Trendelenburg position or not being able to move the surgical instruments freely in the abdominal cavity can be frustrating, especially for naïve robotic surgeons (ie, those at the beginning of the learning curve for this pr...

متن کامل

Cerebral haemodynamic physiology during steep Trendelenburg position and CO(2) pneumoperitoneum.

BACKGROUND The steep (40°) Trendelenburg position optimizes surgical exposure during robotic prostatectomy. The goal of the current study was to elucidate the influence of this patient positioning on cerebral blood flow and zero flow pressure (ZFP), and to assess the validity of different methods of evaluating ZFP. METHODS In 21 consecutive patients who underwent robotic endoscopic radical pr...

متن کامل

Changes in intraocular pressure and optic nerve sheath diameter in patients undergoing robotic-assisted laparoscopic prostatectomy in steep 45° Trendelenburg position

BACKGROUND To evaluate changes in intraocular pressure (IOP) and intracerebral pressure (ICP) reflected by the optic nerve sheath diameter (ONSD) in patients undergoing robotic-assisted laparoscopic prostatectomy (RALP) in permanent 45° steep Trendelenburg position (STP). METHODS Fifty-one patients undergoing RALP under a standardised anaesthesia. IOP was perioperatively measured in awake pat...