Clinical Accuracy and Safety Using the SynchroMed II Intrathecal Drug Infusion Pump

نویسندگان

  • Kelly Wesemann
  • Robert J. Coffey
  • Mark S. Wallace
  • Ye Tan
  • Steven Broste
  • Asokumar Buvanendran
چکیده

BACKGROUND AND OBJECTIVES We evaluated the infusion accuracy and device-related safety of implantable drug infusion pumps in subjects with chronic pain or severe spasticity. METHODS Nine centers in the United States enrolled patients receiving intrathecal drug delivery systems to manage chronic pain and/or severe spasticity. Infusion accuracy was assessed at 6 and 12 months by comparing syringe-measured delivered volumes to programmer-predicted volumes. Safety was evaluated through analysis of adverse events. Separate laboratory testing conducted by the manufacturer also evaluated infusion accuracy. RESULTS Eighty of 82 enrolled subjects were implanted. Sixty-five and 54 subjects, respectively, were analyzable for accuracy at 6 and 12 months. On average at 6 months, the pumps were measured to have delivered 1% more than the programmed delivery volume. Analyzed on a per-refill basis, the pumps delivered, on average, 2.5% more than the programmed delivery volume. Differences between per-refill means versus per-subject cumulative means were due to limitations in clinicians' ability to precisely visualize single small syringe-volume differences, or possibly incomplete withdrawal of fluid from the pump. Laboratory testing demonstrated a per-refill mean accuracy error of minus 2.4%. Because average observed flow-rate error at 6 and 12 months (1% overinfusion) was derived from pump residual volume measurements by syringe and carried out in a clinical setting, clinical volume ratios were larger than direct volume measurements by weight observed in the laboratory. No deaths, permanent injuries, or unanticipated adverse device effects occurred. CONCLUSIONS The pump accurately delivered intrathecal medication in the clinical setting of this study. Adverse events were similar in nature and severity to those described in the product labeling and literature.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

An in vivo canine study to assess granulomatous responses in the MedStream Programmable Infusion System (TM) and the SynchroMed II Infusion System®.

OBJECTIVE A rare, but consistently reported complication of intrathecal (IT) delivery of opioids via programmable implantable infusion pumps is aseptic granuloma formation around the tip of the IT catheter. In the current study, the incidence and severity of IT granuloma formation was assessed for the MedStream Programmable Infusion and SynchroMed II Infusion pumps when delivering saline, baclo...

متن کامل

SynchroMed II intrathecal pump memory errors due to repeated magnetic resonance imaging.

Cancer patients with severe refractory pain are often managed with implantable drug delivery systems (IDDS). The only drugs with US Food and Drug Administration approval for intrathecal use are morphine, ziconotide, and baclofen. Other drugs used and mixed include, hydromorphone, bupivacaine, sufentanil, and fentanyl. These patients often undergo magnetic resonance imaging (MRI) for disease-rel...

متن کامل

Bladder stones – red herring for resurgence of spasticity in a spinal cord injury patient with implantation of Medtronic Synchromed pump for intrathecal delivery of baclofen – a case report

BACKGROUND Increased spasms in spinal cord injury (SCI) patients, whose spasticity was previously well controlled with intrathecal baclofen therapy, are due to (in order of frequency) drug tolerance, increased stimulus, low reservoir volume, catheter malfunction, disease progression, human error, and pump mechanical failure. We present a SCI patient, in whom bladder calculi acted as red herring...

متن کامل

Intrathecal baclofen for dystonia treatment during pregnancy: A case report.

Isolated trochlear nerve palsy as a presenting feature of primary polycythemia rubra vera. ଝ Baclofeno intratecal para el tratamiento de la distonía durante el embarazo: un caso clínico Dear Editor: Baclofen is an anti-spasmodic drug and muscle relaxant indicated for treating spasticity. 1,2 The exact mechanism of action is unclear, although it is believed to be a GABA agonist; it decreases the...

متن کامل

The Pharmacology of Spinal Opioids and Ziconotide for the Treatment of Non-Cancer Pain

BACKGROUND Intrathecal drug delivery has undergone a revitalization following a better understanding of this delivery route and its pharmacokinetics. Driven by patient safety and outcomes, clinicians are motivated to rethink the traditional spinal infusion pump patient selection criteria and indications. We review the current understanding of the pharmacology of commonly employed intrathecal ag...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 39  شماره 

صفحات  -

تاریخ انتشار 2014