Automated peritoneal dialysis with 'on-line'-prepared bicarbonate-buffered dialysate: technique and first clinical experiences.
نویسندگان
چکیده
BACKGROUND Automated peritoneal dialysis (APD) has the possibility of increasing the dialysis efficacy by using higher fill volumes, frequent dialysate exchanges, and tidal techniques. It is then possible to treat patients adequately without residual renal function. The drawbacks of the required high amounts of dialysis solution of up to 30 litres per session are the high costs of lactate-based dialysate bags and difficulties for the patients in handling these bags. So far, bicarbonate-based peritoneal dialysate, which may be more biocompatible, is only available for CAPD in double-chamber bags. In APD this could be overcome by 'on-line' preparation of bicarbonate-buffered dialysate using advanced technologies originally designed for on-line preparation of substitution fluid for haemofiltration. METHODS Four patients without residual renal function were treated with APD five times weekly in a crossover study design. Patients received standard lactate-based (35 mmol/l) treatment (25 litres per session each) in weeks 1 and 3. In week 2 on-line-produced bicarbonate-buffered (37 mmol/l) dialysate was used. This dialysate was prepared by an AK 100 Ultra haemodialysis machine. The machine was modified for adding glucose from a 50% concentrate to the desired concentration of 1.7%. Electrolytes, pH, pCO2, and dialysis efficacy parameters were measured. Microbiological testing was carefully performed. RESULTS Creatinine clearances, Kt/V, and pCO2 did not vary between the different treatment phases, whereas the pH showed a distinct increase during the bicarbonate phase. Repeated determinations of endotoxins and culturing showed no contamination of the dialysate. The composition of the produced dialysate was reproducible with respect to pH, pCO2, sodium, calcium and bicarbonate, whereas the glucose concentration varied by +/- 20%. CONCLUSIONS On-line preparation of PD fluid with the AK 100 Ultra is easy and safe to handle. APD with dialysate containing 37 mmol/l bicarbonate provides improved acid base balance and possibly improved biocompatibility, and may lead to a significant cost reduction. Further development in order to provide smaller machines and more precise ways of achieving a desired dialysate glucose concentration is necessary.
منابع مشابه
Developing a Device for Automated Peritoneal Dialysis
Background: Peritoneal dialysis (PD) is an efficient alternative for hemodialysis. Removal of waste metabolites and excess water from the blood circulation are the two main tasks done during dialysis. These are done by using a filter; in PD, the naturally semi-permeable peritoneal membrane acts as the filter. Automated PD machines control intelligently the operations to enhance the efficiency a...
متن کاملAcid-base profile and predictors of metabolic acidosis in patients undergoing peritoneal dialysis with lactate- and bicarbonate-buffered peritoneal dialysis solutions.
Metabolic acidosis correction is one of the goals of renal replacement therapy. Correction of acidosis in peritoneal dialysis (PD) may be affected by PD modalities such as automated PD (APD) or by new solutions containing a combination of bicarbonate and lactate as a buffer [bicarbonate continuous ambulatory PD (CAPD)]. The aim of the present study was to examine the acid-base status of our PD ...
متن کاملBiocompatibility pattern of a bicarbonate/lactate-buffered peritoneal dialysis fluid in APD: a prospective, randomized study.
BACKGROUND In chronic ambulatory peritoneal dialysis, bicarbonate-buffered fluids, with their neutral pH and less advanced glycosylation end-products (AGE) and glucose degradation products (GDP), have better biocompatibility than conventional peritoneal dialysis (PD) solutions. That difference may be more beneficial in automated peritoneal dialysis (APD), due to its more frequent exchanges and ...
متن کاملBicarbonate/lactate dialysis solution improves in vivo function of peritoneal host defense in rats.
OBJECTIVE To assess the in vivo peritoneal inflammatory reaction in rats dialyzed with neutral, bicarbonate-lactate-buffered dialysis fluid. METHODS Chronic peritoneal dialysis was performed for 4 weeks in Wistar rats with two solutions: (1) 40 mmol/L lactate-buffered fluid, pH 5.2, with a glucose concentration of 2.27 g/dL (Lac); and, (2) 15 mmol/L lactate and 25 mmol/L bicarbonate-buffered ...
متن کاملOn-line haemodiafiltration: state of the art.
Faced with the shortcomings of conventional dialysis on a long-term basis, as illustrated by the dialysis-related pathology, a need for a new strategy exists to improve the overall quality of treatment in end-stage renal failure (ESRF) patients. On-line haemodiafiltration (HDF) seems to be the best therapeutic option to achieve this goal at the present time. By enhancing convective clearances t...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association
دوره 13 12 شماره
صفحات -
تاریخ انتشار 1998