Design of a 7 MeV/u, 217 MHz Injector Linac for Therapy Facilities

نویسندگان

  • B. Schlitt
  • A. Bechtold
  • U. Ratzinger
  • A. Schempp
چکیده

Design ion C (A/q = 3) Operating frequency 216.816 MHz Final beam energy 7 MeV/u Pulse currents after stripper ≈ 100 eμA C ≈ 0.7 mA protons Beam pulse length ≤ 200 μs @ ≤ 5 Hz Duty cycle ≤ 0.1 % Norm. transverse exit beam emittances (95%) 1 ≈ 0.8 π mm mrad Exit momentum spread 1 ±0.15 % Total injector length 2 ≈ 13 m 1 Not including emittance growth effects in the stripper foil. 2 Including the ion sources and up to the foil stripper.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design of the 7 Mev/u, 217 Mhz Injector Linac for the Proposed Ion Beam Facility for Cancer Therapy at the Clinic in Heidelberg

A dedicated clinical synchrotron facility for cancer therapy using energetic proton and ion beams (C, He and O) has been designed at GSI for the Radiologische Universitätsklinik at Heidelberg, Germany. The design of the injector linac is presented. Suitable ion sources are discussed and results of ion source test measurements are reported. The LEBT allows for switching between two ion sources. ...

متن کامل

Design of a Carbon Injector for a Medical Accelerator Complex

A design study of a 7 MeV/u C injector LINAC for a synchrotron for light-ion tumour therapy is presented. The injector consists of a 14.5 GHz ECR ion source, a LEBT line, a 216 MHz RFQ structure of 1.2 m length for acceleration from 6 keV/u to 300 keV/u and a subsequent 216 MHz IH drift tube LINAC of 4.0 m length for acceleration to 7 MeV/u. The IH structure consists of four drift tube sections...

متن کامل

Development of an Rfq-injector for a Therapy-synchrotron1

An accelerator facility for radiotherapy of cancer tumours with ions is proposed for the Radiologische Universitaetsklinik in Heidelberg. Design studies have been done for the synchrotron injector-complex with respect to construction and operation costs as well as to a save and simple handling of the machine [1]. After the source section and a LEBT path the beam will be injected into the RFQ at...

متن کامل

Status of the Linac for the Italian Hadron-Therapy Centre CNAO

The Italian hadron-therapy centre CNAO (Centro Nazionale di Adroterapia Oncologica) [1] is designed for the treatment of tumours with proton and light ion beams and to clinical and radiobiological research. The design consists of two ECR ion sources, a 7 MeV/u injector linac identical to the linac of the Heidelberg ion therapy centre HIT [2][3] and a 400 MeV/u synchrotron. GSI delivers technica...

متن کامل

Development of superconducting crossbar-H-mode cavities for proton and ion accelerators

The crossbar-H-mode (CH) structure is the first superconducting multicell drift tube cavity for the low and medium energy range operated in the H21 mode. Because of the large energy gain per cavity, which leads to high real estate gradients, it is an excellent candidate for the efficient acceleration in high power proton and ion accelerators with fixed velocity profile. A prototype cavity has b...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001