The precision of longitudinal lung function measurements: monitoring and interpretation.

نویسندگان

  • E Hnizdo
  • L Yu
  • L Freyder
  • M Attfield
  • J Lefante
  • H W Glindmeyer
چکیده

BACKGROUND The efficacy of decision making based on longitudinal spirometric measurements depends critically on the precision of the available data, which is determined by the magnitude of the within-person variation. AIMS Firstly, to describe and investigate two statistical methods-a pairwise estimate of within-person standard deviation s(p) and the reliability coefficient G-for use in the monitoring of precision of longitudinal measurements of forced expiratory volume in one second (FEV1). Secondly, to investigate the effect of longitudinal data precision on the detectable excess rate of decline in FEV1. METHODS The authors "monitored" retrospectively on a yearly basis the magnitude of the within-person variation s(p) and the coefficient G in 11 workplace based spirometric monitoring programmes conducted from 1987 to 2001 on 12 729 workers in various industrial plants. RESULTS The plant-specific mean values s(p) (range 122-166 ml) and G (range 0.88-0.95), averaged over all years of follow up, correlated well with the plant-specific within-person standard deviation s(r) (range 130-177 ml) estimated from all longitudinal data. The correlations were 0.90 for s(p) and 0.68 for G. The average precision of the longitudinal FEV1 measurements affected the duration of follow up needed to identify a "true" excess rate of decline in FEV1 in an individual. CONCLUSIONS The results show that monitoring of longitudinal spirometry data precision (1) allows that data precision can be improved or maintained at levels that allow individuals with a rapid decline to be identified at an earlier age; and (2) attaches a measure of precision to the data on which decision making is based.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spirometry Longitudinal Data Analysis Software (SPIROLA) for Analysis of Spirometry Data in Workplace Prevention or COPD Treatment

Chronic obstructive pulmonary disease (COPD) is one of the leading causes of morbidity and mortality. Periodic spirometry is often recommended for individuals with potential occupational exposure to respiratory hazards and in medical treatment of respiratory disease, to prevent COPD or improve treatment outcome. To achieve the full potential of spirometry monitoring in preserving lung function,...

متن کامل

The progress mechanism of track geometrical irregularity focusing on hanging sleepers

This topic is very traditional and basically has been concerned for a long time. A lot of sophisticated vehicle/track interaction model and track dynamic deterioration model have been developed so far. The author also developed a track settlement progress model comprising a vehicle/track interaction model and a track settlement law. Hanging sleepers are usually caused more or less by the dyn...

متن کامل

Limits of longitudinal decline for the interpretation of annual changes in FEV1 in individuals.

OBJECTIVE Spirometry-based screening programmes often conduct annual assessment of longitudinal changes in forced expiratory volume in 1 second (FEV1) to identify individuals with excessive rates of decline. Both the American Thoracic Society (ATS) and the American College of Occupational and Environmental Medicine (ACOEM) recommend a reference limit value of > or =15% for excessive annual decl...

متن کامل

Reduced Lung Function and Progression to Prediabetes: A Prospective Study

Objective: Prediabetes is a state that people have blood glucose levels higher than normal but still not in diabetes range. There is a close relationship between impaired lung function and diabetes mellitus (DM). Reduced lung function can be present before the clinical evidence of diabetes or insulin resistance. Materials and Methods: The total number of subjects in this longitudinal study was ...

متن کامل

A Wireless Electronic Esophageal Stethoscope for Continuous Monitoring of Cardiovascular and Respiratory Systems during Anaesthesia

Background: The basic requirements for monitoring anesthetized patients during surgery are assessing cardiac and respiratory function. Esophageal stethoscopes have been developed for this purpose, but these devices may not provide clear heart and lung sound due to existence of various noises in operating rooms. In addition, the stethoscope is not applicable for continues monitoring, and it is u...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Occupational and environmental medicine

دوره 62 10  شماره 

صفحات  -

تاریخ انتشار 2005