The new advanced membrane gas exchanger.

نویسندگان

  • Denis A Berdajs
  • Eleonora de Stefano
  • Dominique Delay
  • Enrico Ferrari
  • Judith Horisberger
  • Quntin Ditmar
  • Ludwig K von Segesser
چکیده

Current membrane oxygenators are constructed for patients with a body surface under 2.2 m(2). If the body surface exceeds 2.5 m(2), commercially available devices may not allow adequate oxygenation during cardiopulmonary bypass. To address this, a hollow-fiber oxygenator with an enlarged contact surface of 1.81 m(2) was tested. In an experimental set-up, six calves of mean weight 85.4 ± 3 kg were connected to cardiopulmonary bypass. They were randomly assigned to a standard oxygenator (n = 3; ADMIRAL, Euroset, Medola, Italy) with a surface of 1.35 m(2) or to an enlarged surface oxygenator (n = 3; AMG, Euroset). Blood samples were taken before bypass, after 10 min on bypass, and after 1, 2, 5 and 6 h of perfusion. Analysis of variance was used for repeated measurements. The mean flow rate was 6.5 l/min for 6 h. The total oxygen transfer at 6 h was significantly higher in the high-surface group (P < 0.05). Blood trauma, evaluated by plasma hemoglobin and lactate dehydrogenase levels, did not detect any significant hemolysis. Thrombocytes and white blood cell count profiles showed no significant differences between the two groups at 6 h of perfusion (P = 0.06 and 0.80, respectively). At the end of testing, no clot deposition was found in the oxygenator, and there was no evidence of peripheral emboli. The results suggest that the new oxygenator allows very good gas transfer and may be used for patients with a large body surface area.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Advanced Exergoeconomic Analysis of C3MR, MFC and DMR ‎Refrigeration Cycles in an Integrated Cryogenic Process

C3MR, MFC, and DMR processes in an integrated LNG-NGL-NRU structure are investigated using the conventional and advanced exergy and exergoeconomic analyses. The results of advanced exergy analysis reveal that in most of the equipment, the highest amount of irreversibility is occurred because of endogenous exergy destruction. In C3MR process, compressor C5 with 9730 kW; in MFC process, compresso...

متن کامل

Evaluation of an Integrated Cryogenic Natural Gas Process with the Aid of Advanced Exergy and Exergoeconomic Analyses

In this study, an integrated structure of the air separation unit, natural gas liquids recovery equipped with nitrogen removal unit is developed. In this regard, advanced exergy and exergoeconomic analyses are used to examine the irreversibility, possible improvements and the cost of the inefficiencies of the process. The exergy analysis presents information on the origin of the irreversibility...

متن کامل

Experimental Investigation on Hydrodynamic and Thermal Performance of a Gas-Liquid Thermosyphon Heat Exchanger in a Pilot Plant

Waste heat recovery is very important, because not only it reduces the expenditure of heat generation, but also it is of high priority in environmental consideration, such as reduction in greenhouse gases. One of the devices is used in waste heat recovery is heat pipe heat exchanger.Anexperimental research has been carried out to investigate the hydrodynamic and thermal performance of a gas...

متن کامل

A Numerical Study on Using Air Cooler Heat Exchanger for Low Grade Energy Recovery from Exhaust Flue Gas in Natural Gas Pressure Reduction Stations

Heat EXchangers (HEX) that are used in City Gate Station (CGS) systems are modeled numerically to recover the exhaust waste heat. It was tried to find the best viscous model to obtain results in accordance with experimental results and to change the heat exchanger design. This HEX is used for recovering heat from exhaust flue gas with a mixture of 40% water and 60% ethylene glycol as the coolin...

متن کامل

Numerical simulation of a three-layered radiant porous heat exchanger including lattice Boltzmann simulation of fluid flow

This paper deals with the hydrodynamic and thermal analysis of a new type of porous heat exchanger (PHE). This system operates based on energy conversion between gas enthalpy and thermal radiation. The proposed PHE has one high temperature (HT) and two heat recovery (HR1 and HR2) sections. In HT section, the enthalpy of flowing high temperature gas flow that is converted to thermal radiation em...

متن کامل

شبیه‌سازی بازیافت آب و انرژی از گازهای اتلافی صنایع توسط تکنولوژی جدید مبدل چگالندۀ غشایی

A Number of Industries release large amounts of water vapor into the atmosphere through their stacks. The flue gas can be a potential source for obtaining the required water for those industries. Separation process of water vapor by means of membrane condenser exchanger was studied. Numerical simulation of the process was conducted by COMSOL software using computational fluid dynamics. Simulati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Interactive cardiovascular and thoracic surgery

دوره 13 6  شماره 

صفحات  -

تاریخ انتشار 2011