Central corneal thickness and intraocular pressure in the Cameroonian nonglaucomatous population
نویسندگان
چکیده
AIM We performed a prospective, analytical study from 01 January to 31 March 2009 in the Ophthalmology Unit of the Gyneco-Obstetric and Pediatric Hospital of Yaounde, aiming to determine the profile of central corneal thickness (CCT) in the Cameroonian nonglaucomatous black population and its relationship with intraocular pressure (IOP). RESULTS AND DISCUSSION Four hundred and eighty-five patients (970 eyes) meeting our inclusion criteria were selected for this study. The average CCT was 529.29 +/- 35.9 mum in the right eye (95% confidence interval [CI]: 526.09-532.49), 528.19 +/- 35.9 mum in the left eye (95% CI: 524.99-531.40) and 528.74 +/- 35.89 mum in both eyes (95% CI: 526.48-531.00), range 440 to 670 mum. The average IOP was 13.01 +/- 2.97 mmHg in both eyes (95% CI: 12.82-13.19). A rise in CCT by 100 mum was followed by an increase in IOP of about 2.8 mmHg (95% CI: 2.3-3.6) for both eyes taken together. Linear regression analysis showed that corneal thickness was negatively correlated with age and IOP was positively related with age. CONCLUSION CCT in the Cameroonian nonglaucomatous black population was found to be lower compared with CCT values in Caucasian and Asian populations. On the basis of reference values ranging between 527 and 560 mum, an adjustment of IOP values by a correction factor is required for many Cameroonian patients. This will improve the diagnosis and follow-up of glaucoma by helping to detect true ocular hypertension.
منابع مشابه
Comparison of Goldmann and Pascal tonometry in relation to corneal hysteresis and central corneal thickness in nonglaucomatous eyes
OBJECTIVE To compare measurements obtained by Goldmann applanation tonometry (GAT) and Pascal dynamic contour tonometry (DCT), and to study their relationship to corneal thickness and biomechanical properties in nonglaucomatous eyes. METHODS This is a prospective and randomized study of 200 eyes from 200 non-glaucomatous subjects who underwent intraocular pressure (IOP) measurements by GAT an...
متن کاملبررسی ارتباط بین ضخامت مرکز قرنیه و میزان فشار داخل چشمی اندازه گیری شده با تونومتر گلدمن
To determine the effect of central corneal thickness (CCT) on measured intraocular pressure (IOP) and evaluating the relationship between them in each of the groups of patients including: Normal subjects, ocular hypertension patients and patients with primary open angle glucoma (POAG). Correlation between intraocular pressure (Measured by Goldman applanation tonometer) and central corneal thick...
متن کاملCentral corneal thickness and thickness of the lamina cribrosa in human eyes.
PURPOSE Since central corneal thickness may inversely influence the amount and rate of progression of glaucomatous optic nerve damage and because lamina cribrosa thickness may be of importance in susceptibility to glaucoma, it was the purpose of the present study to evaluate whether central corneal thickness is related to lamina cribrosa thickness. METHODS The histomorphometric study included...
متن کاملIntraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملPlanimetrically determined vertical cup/disc and rim width/disc diameter ratios and related factors.
PURPOSE To evaluate the distribution and factors related to planimetrically determined vertical cup/disc (v-C/D) and rim width/disc diameter (Rw/Dd) ratios of the optic discs in a population-based study of Japanese subjects without glaucoma. METHODS Of 4632 eligible residents 40 years of age and older, 3762 residents underwent a detailed ocular examination including sequential optic disc ster...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 4 شماره
صفحات -
تاریخ انتشار 2010