The sphygmography measuring converter “pressure – frequency” dynamic characteristics examination

نویسندگان

  • F. F. Kolpakov
  • S. S. Slavinsky
چکیده

Dynamic characteristics of a sphygmography measuring converter definition technique on the basis of the state-of-the-art analysis of dynamic characteristics definition modes are presented. An apparatus for the transmitter dynamic characteristics definition is offered as well.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Basic Characteristics of Digitally Controlled Boost Type Dc-dc Converter

This paper presents the basic characteristics of the digitally controlled boost type dc-dc converter. The static and dynamic characteristics of the dc-dc converter with the digital PID control are discussed. Especially, it is examined that the A-D conversion timing and anti-aliasing filter’s cut-off frequency affect the dynamic and static characteristics. As a result, when the anti-aliasing fil...

متن کامل

Sliding Mode Control of a Bidirectional Buck/Boost DC-DC Converter with Constant Switching Frequency

In this paper, sliding mode control (SMC) for a bidirectional buck/boost DC-DC converter (BDC) with constant frequency in continuous conduction mode (CCM) is discussed. Since the converter is a high-order converter, the reduced-order sliding manifold is exploited. Because of right-half-plan zero (RHPZ) in the converter’s duty ratio to output voltage transfer function, sliding mode current...

متن کامل

Low-cost current-to-voltage converter for DC measurements in a wide dynamic range

Abstrac t-A logarithmic current-to-voltage converter for measuring DC currents in a wide dynamic range (from 1 pA to 1 mA) is described here. The converter is based on an operational amplifier circuit with a standard commercially-available LED diode used as a nonlinear feedback. A temperature compensation method requiring only one reference amplifier was used. This significantly reduces the com...

متن کامل

Plunging Airfoil Load Characteristics Equipped with Gurney Flap

Numerous experiments have been conducted on plunging Eppler 361 airfoil in a subsonic wind tunnel. The experimental tests involved measuring the surface pressure distribution over the airfoil at Re=1.5×105. The airfoil was equipped with Gurney flap(heights of 2.6, 3.3 and 5% chord) and plunged at 6cm amplitude. The unsteady aerodynamic loads were calculated from the surface pressure measurement...

متن کامل

The Effect of Pressure-Inducing System of Transducers of Dynamic Pressure Measurement

In this paper, we will r1rst introduce the methods and instrument or the indicated diagram of microcomputer testing compressor, and then we will emphasize the building of mathematical models of pressure-inducting system of the pressure transducer. Based on the analysis of frequency response, we will discuss how to reduce the distrubance. We hope our exploration may be helprul to those who are r...