New developments in planar array infrared spectroscopy.
نویسندگان
چکیده
A planar array infrared (PA-IR) spectrograph offers several advantages over other infrared approaches, including high acquisition rate and sensitivity. However, it suffers from some important drawbacks, such as a limited spectral range and a significant curvature of the recorded spectral images, which still need to be addressed. In this article, we present new developments in PA-IR spectroscopy that overcome these drawbacks. First, a data processing method for the correction of the curvature observed in the spectral images has been developed and refined. In addition, a dual-beam instrument that allows the simultaneous recording of two independent spectral images has been developed. These two improvements have been combined to demonstrate the real-time background correction capability of PA-IR instruments. Finally, the accessible spectral range of the PA-IR spectrograph has been extended to cover simultaneously the methylene stretching (3200-2800 cm(-1)) and the finger-print (2000-1000 cm(-1)) spectral regions.
منابع مشابه
Planar array infrared emission spectroscopy.
Planar array infrared spectroscopy (PA-IR) is shown to be a powerful new approach to infrared emission spectroscopy (IRES). A proof-of-concept study of selected polymers indicates that PA-IRES allows acquisition of emission spectra with a high signal-to-noise ratio at temperatures as low as 80 degrees C. It is shown that a time resolution below 20 ms is readily achievable for time-resolved char...
متن کاملA faster approach to infrared rheo-optics using a planar array infrared spectrograph.
Infrared rheo-optics combines dynamic mechanical analysis with infrared spectroscopy to provide molecular level information about the segmental reorientation and the changes in local environment associated with the dynamic deformation of polymers. Up to now, the application of this technique has been limited by the amount of time necessary to perform the experiments. In this article, we demonst...
متن کاملPerformance and application of a new planar array infrared spectrograph operating in the mid-infrared (2000-975 cm(-1)) fingerprint region.
A no-moving-part planar array infrared spectrograph (PA-IR) equipped with a 256 x 256 mercury cadmium telluride (MCT) focal plane array has been designed and constructed. The performance of the instrument, whose frequency range extends from 2000-975 cm(-1), has been assessed in terms of resolution, bandwidth, and signal-to-noise ratio. The PA-IR spectrograph is able to record spectra with an 8....
متن کاملTime-resolved IR studies of monolayer self-assembly on a gold substrate using planar array infrared (PA-IR) spectroscopy.
Time-resolved and spatially resolved infrared spectra (line images) of self-assembled monolayers of octadecylthiol (ODT) on gold substrates were investigated by planar array infrared (PA-IR) spectroscopy, with a grazing incidence reflection attachment. It was observed that PA-IR spectra with a good signal-to-noise ratio that is comparable to those obtained from Fourier transform infrared spectr...
متن کاملA Thinning Method of Linear And Planar Array Antennas To Reduce SLL of Radiation Pattern By GWO And ICA Algorithms
In the recent years, the optimization techniques using evolutionary algorithms have been widely used to solve electromagnetic problems. These algorithms use thinning the antenna arrays with the aim of reducing the complexity and thus achieving the optimal solution and decreasing the side lobe level. To obtain the optimal solution, thinning is performed by removing some elements in an array thro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Applied spectroscopy
دوره 59 2 شماره
صفحات -
تاریخ انتشار 2005