Geometrical stress-reducing factors in the anisotropic porcine heart valves.
نویسندگان
چکیده
This study carries out a detailed parameter study based on a nonlinear anisotropic finite-element model published previously. The aim of this study is to identify the stress-reducing influences from geometrical parameters such as stent height, valve diameter, and the nonuniform thickness of porcine aortic valves under static loading condition. The anisotropy of the valve is considered to be transversely isotropic with fibers oriented along the circumferential directions, which enables us to use a simple anisotropic constitutive model using uniaxial experimental data. The results showed that in general, higher stent height and smaller diameter combined with nonuniform thickness give rise to a much more reduced overall stress level. Although the absolute values of the peak stresses may be influenced by the detailed orientations of fibers, the trends of the stress variation with the geometrical factors seem to be qualitatively consistent within the parameter ranges considered.
منابع مشابه
A nonlinear anisotropic model for porcine aortic heart valves.
The anisotropic property of porcine aortic valve leaflet has potentially significant effects on its mechanical behaviour and the failure mechanisms. However, due to its complex nature, testing and modelling the anisotropic porcine aortic valves remains a continuing challenge to date. This study has developed a nonlinear anisotropic finite element model for porcine heart valves. The model is bas...
متن کاملTri-layered elastomeric scaffolds for engineering heart valve leaflets.
Tissue engineered heart valves (TEHVs) that can grow and remodel have the potential to serve as permanent replacements of the current non-viable prosthetic valves particularly for pediatric patients. A major challenge in designing functional TEHVs is to mimic both structural and anisotropic mechanical characteristics of the native valve leaflets. To establish a more biomimetic model of TEHV, we...
متن کاملModification of pump as turbine as a soft pressure reduction systems (SPRS) for utilization in municipal water network
Pressure Reducing Valves (PRV) are being used for decreasing the existing extra pressure in the water distribution network. however, they dissipate a considerable amount of energy. Therefore, the idea of application of Soft Pressure Reducing Systems (SPRS) is proposed, where a PRV is replaced by a hydropower station. The heart of An SPRS is the turbo-generator. One of the advantages of this typ...
متن کاملFresh porcine cardiac valves are not rejected in primates.
OBJECTIVE Transplanted porcine hearts are hyperacutely rejected by human immunoglobulin M antibodies against a porcine vascular endothelial molecule, galactose alpha-1,3-galactose, with ensuing human complement activation and membrane attack complex deposition. It is unclear, however, whether porcine valve endothelium triggers a similar immune response. We sought to investigate whether fresh po...
متن کاملPorcine heart valves produce a protein that induces cell-mediated connective tissue degradation: II. Biochemical properties of the partially purified protein.
A cardiac catabolic factor (CCF) has been partially purified from serum-free medium conditioned by minced porcine heart valves. CCF was prepared by a series of chromatographic techniques and compared directly with porcine synovial catabolin purified by the same protocol. CCF displayed a somewhat higher molecular weight (Mr 21,000) and isoelectric point (pI 5.2) than did synovial catabolin (Mr 1...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of biomechanical engineering
دوره 125 5 شماره
صفحات -
تاریخ انتشار 2003