Performance of a new leadless implantable cardiac monitor in detecting and quantifying atrial fibrillation: Results of the XPECT trial.
نویسندگان
چکیده
BACKGROUND Current methods for detecting atrial fibrillation (AF) have limited diagnostic yield. Continuous monitoring with automatic arrhythmia detection and classification may improve detection of symptomatic and asymptomatic AF and subsequent patient treatment. The study purpose was to quantify the performance of the first implantable leadless cardiac monitor (ICM) with dedicated AF detection capabilities. METHODS AND RESULTS Patients (n=247) with an implanted ICM (Reveal XT, Medtronic Inc, Minneapolis, Minn) who were likely to present with paroxysmal AF were selected. A special Holter device stored 46 hours of subcutaneously recorded ECG, ICM markers, and 2 surface ECG leads. The ICM automatic arrhythmia classification was compared with the core laboratory classification of the surface ECG. Of the 206 analyzable Holter recordings collected, 76 (37%) contained at least 1 episode of core laboratory classified AF. The sensitivity, specificity, positive predictive value, and negative predictive value for identifying patients with any AF were 96.1%, 85.4%, 79.3%, and 97.4%, respectively. The AF burden measured with the ICM was very well correlated with the reference value derived from the Holter (Pearson coefficient=0.97). The overall accuracy of the ICM for detecting AF was 98.5%. CONCLUSIONS In this ICM validation study, the dedicated AF detection algorithm reliably detected the presence or absence of AF and the AF burden was accurately quantified. The ICM is a promising new diagnostic and monitoring tool for the clinician to treat AF patients independently of symptoms. Long-term studies are needed to evaluate the clinical benefits of the technology.
منابع مشابه
Twiddler syndrome causing an inappropriate implantable cardioverter-defibrillator shock.
Yang S, Bailleul C, Morillo CA, Carlson M, Themeles E, Kaufman ES, Hohnloser SH. Subclinical atrial fibrillation and the risk of stroke. N Engl J Med 2012;366:120–129. 14. Allison PD. Survival Analysis Using the SAS: A Practical Guide. 1st ed. Gary, NC: SAS Institute Inc., 1995. 15. Lamas G.Howmuchatrial fibrillation is too muchatrial fibrillation?N Engl JMed 2012; 366:178–180. 16. Hindricks G,...
متن کاملEvaluation of transesophageal echocardiography in detecting cardiac sources of emboli in ischemic stroke patients
Background: Embolus is one of the causes of ischemic stroke that can be due to cardiac sources such as valvular heart diseases and atrial fibrillation and atheroma of the aorta. Transesophageal echocardiography (TEE) is superior in identifying potential cardiac sources of emboli. Due to insufficient data on TEE findings in ischemic stroke in Iran, the present study was done to evaluate TEE in...
متن کاملتأثیر ویتامین C در کاهش بروز فیبریلاسیون دهلیزی بعد از عمل جراحی بایپس کرونری: کارآزمایی بالینی تصادفی دوسوکور
Background: Atrial fibrillation is the most common arrhythmia after cardiac surgery. Vitamin C as an antioxidant has an important role in reducing the incidence of postop-erative atrial fibrillation. The present study aimed at administrating vitamin C as a way to reduce the incidence of post-CABG atrial fibrillation. Methods: In this double-blind, parallel clinical trial, 170 patients with cor...
متن کاملInvestigating the Effect of Inflammation on Atrial Fibrillation Occurrence by Measuring Highly Sensitive C-reactive Protein (hs-CRP)
Introduction: Atrial fibrillation (AF) is the most prevalent cardiac arrhythmias that cardiologists and internists encounter. The goal of this article is to clarify an overview of the evidence linking inflammation to AF existence, which may highlight the effect of some pharmacological agents that have genuine potential to reduce the clinical burden of AF by modulating inflammatory pathways. Mat...
متن کاملThe effects of Vitamin C on Inflammatory Markers and Atrial Fibrillation in Patients Undergoing Coronary Artery Bypass Surgery in Bushehr Heart Center: A Randomized Controlled Clinical Trial
Background: Coronary artery bypass graft surgery (CABG) with cardiopulmonary bypass pump may cause systemic inflammatory reactions by releasing cytokines which leads to multiple organ failure. Vitamin C has anti-inflammatory and antioxidant properties. The study aimed to determine the effect of vitamin C on inflammatory markers and atrial fibrillation in patients undergoing CABG. Materials and ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation. Arrhythmia and electrophysiology
دوره 3 2 شماره
صفحات -
تاریخ انتشار 2010