The invention of new anterior spinal instrumentation prototype: a structural analysis of KKU expandable cage.

نویسندگان

  • Surachai Sae-Jung
  • Kitti Jirarattanaphochai
  • Sukit Saengnipanthkul
چکیده

OBJECTIVE Report the invention and structural analysis of the new model of anterior spinal instrumentation (KKU expandable cage) that is expandable for space filling after vertebral body resection while simultaneously stabilize the upper vertebra with the lower vertebra, to tolerate the thoracolumbar physiologic load and augment the interbody arthrodesis of the spine. MATERIAL AND METHOD The new model of expandable anterior spinal instrumentation, named KKU expandable cage, was invented and designed using the computer. The structural property of this instrumentation was tested and analyzed using the computer based structural analysis software. RESULTS The KKU expandable cage made out of 316L stainless steel is 0.0301044 kg in mass and 3.76305 x 10(-6) m3 for volume. The outer diameter of the device is 23 mm and the height can expand from 20 mm to 35 mm for space filling after thoracolumbar vertebrectomy. The stress in the device after applying the maximal thoracolumbar physiologic compression load (1250N) is between 11692.7 N/m2 to 94.7266 x 10(6) N/m2, less than compression strength of the 316L stainless steel (170 x 10(6) N/m2). CONCLUSION The stainless steel 316 L KKU expandable cage for anterior spinal instrumentation can withstand the maximal thoracolumbar physiologic compression load without failure whereas its expandable property enable it to fill and fit in the space reaching the height of 35 mm. Therefore, the insertion of this device into a space after thoracolumbar or lumbar corpectomy or vertebrectomy for the vertebral osteomyelitis or vertebral metastasis is appropriate. The device can also stabilize the spine and tolerate the maximal physiologic compression load of the thoracolumbar vertebrae. Therefore, the device helps decrease the need for bone graft or bone substitute in these patients.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Adult Degenerative Scoliosis with Spinal Stenosis Treated with Stand-Alone Cage via an Extreme Lateral Transpsoas Approach; a Case Report and Literature Review

We report the case of a 73-year-old female with severe degenerative scoliosis and back and leg pain that wassuccessfully treated with stand- alone cages via an extreme lateral transpsoas approach. This patient had declinedopen surgery and instrumentation due to her advanced age concerns about potential side effects.

متن کامل

The Effects of Posterior Spinal Fusion in Patients with Limitations of Anterior Approach: The Experience of Six Cases

Background & Importance: Spinal deformity is one of the most common disorders among the vertebral diseases that results from unnatural curvatures of spine, such as scoliosis and kyphosis. Spinal fusion surgery is used most commonly to treat certain types of spinal deformity. Herein, we reported the efficacy of posterior spinal fusion accompanied by instrumentation in patients with the...

متن کامل

The transmission of stress to grafted bone inside a titanium mesh cage used in anterior column reconstruction after total spondylectomy: a finite-element analysis.

STUDY DESIGN A finite-element study of posterior alone or anterior/posterior combined instrumentation following total spondylectomy and replacement with a titanium mesh cage used as an anterior strut. OBJECTIVES To compare the effect of posterior instrumentation versus anterior/posterior instrumentation on transmission of the stress to grafted bone inside a titanium mesh cage following total ...

متن کامل

Spinal Decompression and Stabilization: Expandable PLIF Cages over TLIF Cages for Spinal Fusion

Study design: An in vitro biomechanical flexibility and fatigue test comparing two different lumbar interbody fusion cages using mono segmental lumbar spine specimens. Objective: To investigate and compare the stabilizing effect of a transforaminal lumbar interbody fusion (TLIF) cage against an expandable posterior lumbar interbody fusion (PLIF) cage. Method: Six intact human lumbar spine segme...

متن کامل

L5 vertebral osteomyelitis treated with L5 corpectomy and anterior instrumentation: case report

STUDY DESIGN  A case report. OBJECTIVE  Pyogenic osteomyelitis is the most common form of vertebral infection and typically resolves following conservative treatment with antibiotics administered long term and immobilization. In cases of spinal instability, severe neurological deficit or disease refractory to medical management, neurosurgical intervention is warranted. Historically, these pat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of the Medical Association of Thailand = Chotmaihet thangphaet

دوره 90 8  شماره 

صفحات  -

تاریخ انتشار 2007