Effect of multisite pacing on ventricular coordination.

نویسندگان

  • C Varma
  • P O'Callaghan
  • N G Mahon
  • K Hnatkova
  • W McKenna
  • A J Camm
  • E Rowland
  • S J D Brecker
چکیده

OBJECTIVE To determine the effect of multisite pacing on left ventricular function. DESIGN Prospective observational study. PATIENTS 18 patients with heart failure with a dilated poorly functioning left ventricle (LV) and left bundle branch block. INTERVENTIONS Pacing for 5 minutes in random order at the right ventricle (RV) apex, RV outflow tract, mid posterolateral LV, RV apex and LV simultaneously, and RV outflow tract and LV simultaneously. The best achieved measurements with RV, LV, and biventricular pacing were compared. MAIN OUTCOME MEASURES LV dimension, filling characteristics, and long axis indices were measured on echocardiography simultaneously with LV pressure. Cycle efficiency (%)--that is, the ratio of the area of the acquired pressure dimension loop to that of the ideal loop for that segment--quantified coordination. RESULTS The pacing site that gave the best achieved cycle efficiency differed between patients (biventricular in five, LV in two, RV in seven, and no site in four). In patients with baseline incoordination (cycle efficiency < or = 72%, n = 12) cycle efficiency improved significantly with RV pacing (cycle efficiency 76%, p = 0.01) but not with LV (65%) or biventricular (67%) pacing. LV based pacing induced premature short axis contraction in a subset of patients (n = 4), which was associated with a prolonged time from the Q wave on the ECG to the onset of inward movement of the long axis (from apex to mitral ring): biventricular 145 ms, LV 105 ms, RV 85 ms (biventricular v RV, p < 0.05). Excluding patients with baseline incoordination in whom premature activation occurred, pacing at all sites led to a similar increase in cycle efficiency (RV 78%, LV 72%, biventricular 73%). CONCLUSIONS Ventricular coordination can be improved with pacing in patients with baseline incoordination. Short and long axis fibres may be asynchronised in a subset of patients with LV or biventricular pacing, which may worsen coordination. The clinical significance of these findings remains to be defined.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Acute haemodynamic comparison of multisite and biventricular pacing with a quadripolar left ventricular lead.

AIMS Pacing from multiple sites in the left ventricle (LV) may bring about further resynchronization of the diseased heart compared with biventricular (BiV) pacing. We compared acute haemodynamic response (LV dP/dtmax) of multisite and BiV pacing using a quadripolar LV lead. METHODS AND RESULTS In 21 patients receiving cardiac resynchronization therapy, a quadripolar LV lead and conventional ...

متن کامل

No incremental benefit of multisite atrial pacing compared with right atrial pacing in patients with drug refractory paroxysmal atrial fibrillation.

OBJECTIVE To evaluate the incremental antifibrillatory effect of multisite atrial pacing compared with right atrial pacing in patients with drug refractory paroxysmal atrial fibrillation paced for arrhythmia prevention alone. METHODS In 20 of these patients (mean (SD) age 64 (8) years; 14 female, six male), a single blinded randomised crossover study was performed to investigate the increment...

متن کامل

A review of multisite pacing to achieve cardiac resynchronization therapy.

Non-response to cardiac resynchronization therapy remains a significant problem in up to 30% of patients. Multisite stimulation has emerged as a way of potentially overcoming non-response. This may be achieved by the use of multiple leads placed within the coronary sinus and its tributaries (dual-vein pacing) or more recently by the use of multipolar (quadripolar) left ventricular pacing leads ...

متن کامل

Benefits of endocardial and multisite pacing are dependent on the type of left ventricular electric activation pattern and presence of ischemic heart disease: insights from electroanatomic mapping.

BACKGROUND There is considerable heterogeneity in the myocardial substrate of patients undergoing cardiac resynchronization therapy (CRT), in particular in the etiology of heart failure and in the location of conduction block within the heart. This may account for variability in response to CRT. New approaches, including endocardial and multisite left ventricular (LV) stimulation, may improve C...

متن کامل

Abrupt disruption of remote monitoring transmission as an indicator of safe backup mode

963–9. 21. Rinaldi CA, Burri H, Thibault B, Curnis A, Rao A, Gras D et al. A review of multisite pacing to achieve cardiac resynchronization therapy. Europace 2015;17:7–17. 22. Biffi M, Foerster L, Eastman W, Eggen M, Grenz NA, Sommer J et al. Effect of bipolar electrode spacing on phrenic nerve stimulation and left ventricular pacing thresholds an acute canine study. Circ Arrhythmia Electrophy...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Heart

دوره 87 4  شماره 

صفحات  -

تاریخ انتشار 2002