A new device for dynamic ventilation-analogue mechanostimulation of pliant tissue layers.
نویسندگان
چکیده
The experimental mechanostimulation of biological cell and tissue test samples has become a standard method in biomechanics research. In order to apply a static or a dynamic mechanical load on biological tissue a variety of different devices for the mechanostimulation have been developed. While cyclic load applications are typically restricted to sinusoidal or rectangular stimulation patterns, a device for more complex dynamic stimulation patterns which would simulate, for instance, the dynamics during mechanical ventilation does not exist. The dynamic alveolar recruitment/derecruitment has been identified as one of the main causes of ventilator-induced lung injury. Therefore, there is a demand for an experimental ventilation-analogue mechanostimulation of the pulmonary cells and tissue. Here, we present our mechanostimulator combined with a new driving system which is able to produce the ventilation-analogue patterns of a dynamic mechanostimulation. In an experimental setting where the test samples were simulated by silicone-membranes in single-, double- and fourfold membrane configuration, we varied the stimulation amplitude from 5% to 60% surface increase and stimulation frequencies ranging from 15/min to 2000/min. Furthermore, the frequency components of mechanical load applied to the sample at sinusoidal, rectangular and ventilation- analogue mechanostimulations were analyzed by means of a Fast Fourier Transform (FFT). The system allows for a homogeneous mechanostimulation with various temporal profiles which may include frequency components of up to 20 Hz. The relative amount of mechanical load applied to the sample at the main stimulation frequency was 76% during sinusoidal stimulation, 35% during the rectangular stimulation, and 29% to 42% during ventilation analogue stimulation.
منابع مشابه
Developing and Validating a New Wireless Wearable Device for Balance Measurement in Sport and Clinical Setting
One of the new clinical techniques to assess the lower body parameters is the wearable ultrasonic sensors. The device which can measure the static and dynamic balance abilities in sport and clinical setting by the traveled signals of ultrasonic transmitter and receiver between two feet was developed and validated. The new device consisted of a pressure gauge and a digital centimeter indicator a...
متن کاملIntroducing a bony composite as tissue equivalent for radiotherapy phantoms
The use of a device that simulates the actual condition, as well as being equivalent to the human body in materials and tissues, and having the capability of acting like internal motions of human body is necessary to investigate and simulate the motion of a tumor in radiotherapy and to evaluate dosimetrical coverage of the dynamic target. This device which is called the dynamic phantom should s...
متن کاملBone Tissue Engineering: a Mini-Review
Despite advances in bone tissue engineering, auto grafts from intra-oral or extra-oral donor sites are still the gold standard for treatment of large craniomaxillofacial defects. Biomaterial development, application of growth factor, and stem cells, open new gateway to bone regeneration studies, but real translation from bench to bedside have not yet happened. In this review article, a number o...
متن کاملThe LMACTrach, a new approach for endotracheal intubation: Apilot study in 100 patients undergoing elective surgery
AbstractBackgroundand endotracheal intubation under direct vision in both anticipated and unexpecteddifficult intubation situations.: The LMA CTrach system is a new device for airway managementMethodsdifferent types of elective surgeries. After randomly selecting the patients for intubationwith this new device, the airway characteristics, height, weight, dental overbiteand thyromental distance ...
متن کاملA Convolutional Neural Network based on Adaptive Pooling for Classification of Noisy Images
Convolutional neural network is one of the effective methods for classifying images that performs learning using convolutional, pooling and fully-connected layers. All kinds of noise disrupt the operation of this network. Noise images reduce classification accuracy and increase convolutional neural network training time. Noise is an unwanted signal that destroys the original signal. Noise chang...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Acta of bioengineering and biomechanics
دوره 14 4 شماره
صفحات -
تاریخ انتشار 2012