Diagnosing lysosomal storage diseases in a Brazilian non-newborn population by tandem mass spectrometry
نویسندگان
چکیده
OBJECTIVES High-throughput mass spectrometry methods have been developed to screen newborns for lysosomal storage disorders, allowing the implementation of newborn screening pilot studies in North America and Europe. It is currently feasible to diagnose Pompe, Fabry, Gaucher, Krabbe, and Niemann-Pick A/B diseases, as well as mucopolysaccharidosis I, by tandem mass spectrometry in dried blood spots, which offers considerable technical advantages compared with standard methodologies. We aimed to investigate whether the mass spectrometry methodology for lysosomal storage disease screening, originally developed for newborns, can also discriminate between affected patients and controls of various ages. METHODS A total of 205 control individuals were grouped according to age and subjected to mass spectrometry quantification of lysosomal α-glucosidase, β-glucocerebrosidase, α-galactosidase, acid sphingomyelinase, galactocerebrosidase, and α-L-iduronidase activities. Additionally, 13 affected patients were analyzed. RESULTS The median activities for each enzyme and each age group were determined. Enzyme activities were significantly lower in individuals aged older than 18 years compared with those in newborns. Affected patients presented enzymatic activities corresponding to less than 20% of the age-matched controls. CONCLUSIONS Our data indicate that the mass spectrometry methodology can be used for the screening of lysosomal storage diseases in non-newborn patients. However, for some diseases, such as Fabry and mucopolysaccharidosis I, a combination of biochemical and clinical data may be necessary to achieve accurate diagnoses.
منابع مشابه
Triplex tandem mass spectrometry assays for the screening of 3 lysosomal storage disorders in a Korean population.
BACKGROUND We evaluated the performance of triplex tandem mass spectrometry (MS/MS) assays using dried blood spots (DBSs) to screen for 3 lysosomal storage disorders (LSDs): Pompe, Fabry, and Gaucher diseases. METHODS An Acquity UPLC CSH C18 column (Waters) and a TQD triple quadrupole mass spectrometer (Waters) in the multiple reaction monitoring (MRM) mode were used to evaluate the precision...
متن کاملDataset and standard operating procedure for newborn screening of six lysosomal storage diseases: By tandem mass spectrometry
In this data article we provide a detailed standard operating procedure for performing a tandem mass spectrometry, multiplex assay of 6 lysosomal enzymes for newborn screening of the lysosomal storage diseases Mucopolysaccharidosis-I, Pompe, Fabry, Niemann-Pick-A/B, Gaucher, and Krabbe, (Elliott, et al., 2016) [1]. We also provide the mass spectrometry peak areas for the product and internal st...
متن کاملImproved Reagents for Newborn Screening of Mucopolysaccharidosis Types I, II, and VI by Tandem Mass Spectrometry
Tandem mass spectrometry for the multiplex and quantitative analysis of enzyme activities in dried blood spots on newborn screening cards has emerged as a powerful technique for early assessment of lysosomal storage diseases. Here we report the design and process-scale synthesis of substrates for the enzymes α-l-iduronidase, iduronate-2-sulfatase, and N-acetylgalactosamine-4-sulfatase that are ...
متن کاملTandem Mass Spectrometry Has a Larger Analytical Range than Fluorescence Assays of Lysosomal Enzymes: Application to Newborn Screening and Diagnosis of Mucopolysaccharidoses Types II, IVA, and VI.
BACKGROUND There is interest in newborn screening and diagnosis of lysosomal storage diseases because of the development of treatment options that improve clinical outcome. Assays of lysosomal enzymes with high analytical range (ratio of assay response from the enzymatic reaction divided by the assay response due to nonenzymatic processes) are desirable because they are predicted to lead to a l...
متن کاملUse of Tandem Mass Spectrometry for Newborn Screening of 6 Lysosomal Storage Disorders in a Korean Population
BACKGROUND We evaluated the performance of multiplex tandem mass spectrometry (MS/MS) in newborn screening for detection of 6 lysosomal storage disorders (LSDs), namely, Niemann-Pick A/B, Krabbe, Gaucher, Fabry, and Pompe diseases and Hurler syndrome. METHODS We revised the conditions and procedures of multiplex enzyme assay for the MS/MS analysis and determined the precision of our enzyme as...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 68 شماره
صفحات -
تاریخ انتشار 2013