Reduced Condenser-Water Flow Rate: Energy-Saving Miracle or Mirage?

ثبت نشده
چکیده

The conventional design of air-conditioning plants using large-tonnage chillers calls for a condenser-water flow rate of 3 gallons-perminute-per-ton-of-refrigeration (GPM/TR). For years, this standard has been thought to offer a good balance between first cost and energy cost. Recently, this conventional design has been challenged by proponents of a 2 GPM/TR design. These proponents suggest that reducing condenser-water flow rate to 2 GPM/TR will save both first cost and energy cost. They posit that the cooling tower, condenser-water pump and piping can all be downsized, thus reducing first cost. Furthermore, although the lower flow rate will penalize energy performance of the chiller, the proponents suggest that the energy savings on the tower and pump will be greater than the energy penalty on the chiller — and that these savings are available in most applications. The legitimacy of these claims was recently scrutinized by Wayne Kirsner, P.E., an independent consulting engineer based in Atlanta, Ga. He conducted an impartial analysis of the impact of 3 versus 2 GPM/TR condenserwater flow rate, which was published in the February 1996 issue of the ASHRAE Journal. His analysis forms the basis upon which this discussion is founded.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Evaluation of Evaporative Cooling for Heat Transfer in the Condenser of Window-Air Conditioners

There is a demand for reduced power consumption in the vapor compression refrigeration cycle. Coefficient of performance of window-air conditioners considerably decreases and power consumption increases under very hot conditions. These problems have encouragecl studies aimed at improving the performance of window-air-conditioners by enhancing the heat transfer rate in the condenser. In this ar...

متن کامل

Thermal Cycle Analysis for an Application to Heat Transport System - Two Stage Condensation System

In the energy-saving research developments in recent years, many types of research project on high performance heat pump systems are under development It is required to estimate the thermodynamic performance of these thermal cycles on a common scale by applying an adequate method. a basic cycle of two stage condensation heat pump system is considered. Steady state conditions are analyzed for th...

متن کامل

Determining the Optimum Inner Diameter of Condenser Tubes Based on Thermodynamic Objective Functions and an Economic Analysis

Abstract: The diameter and configuration of tubes are important design parameters of power condensers. If a proper tube diameter is applied during the design of a power unit, a high energy efficiency of the condenser itself can be achieved and the performance of the whole power generation unit can be improved. If a tube assembly is to be replaced, one should verify whether the chosen condenser ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1999