Developing Barbed Microtip-Based Electrode Arrays for Biopotential Measurement
نویسندگان
چکیده
This study involved fabricating barbed microtip-based electrode arrays by using silicon wet etching. KOH anisotropic wet etching was employed to form a standard pyramidal microtip array and HF/HNO3 isotropic etching was used to fabricate barbs on these microtips. To improve the electrical conductance between the tip array on the front side of the wafer and the electrical contact on the back side, a through-silicon via was created during the wet etching process. The experimental results show that the forces required to detach the barbed microtip arrays from human skin, a polydimethylsiloxane (PDMS) polymer, and a polyvinylchloride (PVC) film were larger compared with those required to detach microtip arrays that lacked barbs. The impedances of the skin-electrode interface were measured and the performance levels of the proposed dry electrode were characterized. Electrode prototypes that employed the proposed tip arrays were implemented. Electroencephalogram (EEG) and electrocardiography (ECG) recordings using these electrode prototypes were also demonstrated.
منابع مشابه
Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier 601 Relative Measurement of Differential Electrode Impedance for Contact Monitoring in a Biopotential Amplifier
In this paper, we propose a simple and relative electrode contact monitoring method. By exploiting the power line interference, which is regarded as one of the worst noise sources for bio-potential measurement, the relative difference in electrode impedance can be measured without a current or voltage source. Substantial benefits, including no extra circuit components, no degradation of the bod...
متن کاملA dry electrophysiology electrode using CNT arrays
We describe the design of a dry electrode sensor for biopotential measurement applications (ENOBIO) designed to eliminate the noise and inconvenience associated to the use of electrolytic gel. ENOBIO uses nanotechnology to remove gel-related noise, as well as maintaining a good contact impedance to minimise interference noise. The contact surface of the electrode will be covered with an array/f...
متن کاملMicrocontroller-based Biopotential Data Acquisition Systems: Practical Design Considerations
Non-invasive bioimpedance measurements are an important part of routine diagnostic procedures. ECG (Electrocardiograph), EEG (Electroencephalograph), EMG (Electromyography) and EOG (Electrooculograph) measurements are amongst the most common non-invasive measurements used for diagnosis. The advances in microcontroller technology over the past 25 years have resulted in general-purpose, low-cost,...
متن کاملIlkka Hokajärvi Electrode Contact Impedance and Biopotential Signal Quality
TAMPERE UNIVERSITY OF TECHNOLOGY Master’s Degree Programme in Electrical Engineering ILKKA HOKAJÄRVI: Electrode Contact Impedance and Biopotential Signal Quality Master of Science Thesis, 66 pages, 3 Appendix pages September 2012 Major: Biomedical Engineering Examiner: Professor Jari Hyttinen
متن کاملInkjet-Printed Flexible Gold Electrode Arrays for Bioelectronic Interfaces
Bioelectronic electrodes are essential in electrophysiology, the scientifi c fi eld that investigates the relationship between electricity and life. Since the advent of electrophysiology in 1783 marked by Luigi Galvani’s experiment of electrical stimulation of a frog leg, electrodes have been used to transduce the body’s ionic current to electronic current and vice versa. [ 1 ] These bioelectro...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 14 شماره
صفحات -
تاریخ انتشار 2014