Theoretical Basis, Laboratory Evidence, and Clinical Research of Chemical Surgery of the Cornea: Cross-Linking
نویسندگان
چکیده
Corneal cross-linking (CXL) is increasingly performed in ophthalmology with high success rates for progressive keratoconus and other types of ectasia. Despite being an established procedure, some molecular and clinical aspects still require additional studies. This review presents a critical analysis of some established topics and others that are still controversial. In addition, this review examines new technologies and techniques (transepithelial and ultrafast CXL), uses of corneal CXL including natural products and biomolecules as CXL promoters, and evidence for in vitro and in vivo indirect effectiveness.
منابع مشابه
Comparative Study of the Effect of Indomethacin and Acetaminophen on Pain after Collagen Cross-Linking Surgery
Introduction: One of the surgeries that needs to be considered after pain and discomfort is corneal cross-linking of the cornea. The aim of this study was to compare the effect of indomethacin and acetaminophen oral surgery before surgery on postoperative pain in the patients undergoing collagen cross-linking surgery. Methods: The present study was a double-blind clinical trial study that was ...
متن کاملHistopathological Finding of Cornea after Collagen Cross-Linking Using Riboflavin and Ultraviolet A in Rabbit
Purpose: To evaluate the histopathological changes of the cornea in rabbit corneas after accelerated collagen cross-linking. Methods: Right eyes of 7 adult New Zealand albino rabbits weighing 1.5 to 2.0 kg were studied. Right eyes of all animals were in the treatment group and left eyes were in the control group. The epithelium of all right eyes was removed and was crossed-linked with riboflavi...
متن کاملLaboratory evaluation of selective in situ refractive cornea collagen shrinkage with continuous wave infrared laser combined with transepithelial collagen cross-linking: a novel refractive procedure
BACKGROUND This research comprised a laboratory evaluation of a novel refractive surgery technique involving sequential corneal subsurface shrinkage-driven reshaping using a continuous wave mid-infrared laser application followed by stiffening via rapid transepithelial higher fluence collagen cross-linking for shape persistence/longevity on cadaver corneas. MATERIALS AND METHODS Ten cadaver c...
متن کاملChemical cross linking versus high energy electron beam cross linking of HDPE: electrical properties study
Cross linking of high density polyethylene (HDPE) was first performed via high energy10 Mev electron beam (EB) irradiation. HDPE was also cross linked withDicumyle peroxide (DCP).The gel content of samples was determined by solvent extraction.Degree of cross linking was evaluated by hot set apparatus; as well .In order to clarify the effectof nature of cross linking, correlation of electrical p...
متن کاملTariq A Alhamad
Understanding the biomechanical properties of the cornea is important in order to develop and improve new reliable standard procedures which can be used effectively to assess corneal behaviour in any disease condition, or before/after any ocular surgery. We believe that the Ocular Response Analyzer (ORA) is the only device that can measures the biomechanical properties of the cornea in vivo. Ho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 2014 شماره
صفحات -