Predicting oxygenator clinical performance from laboratory in-vitro testing.
نویسندگان
چکیده
Knowledge and predictability of oxygenator performance is vital to safe and effective conduct of cardiopulmonary bypass. The determination of oxygenator performance in the laboratory, however, is carried out under a strict set of conditions established by the Association for the Advancement of Medical Instrumentation (AAMI). This performance data is of limited value in the clinical setting where the perfusionist generally operates outside this set of parameters. This study (1) reports the laboratory performance characteristics of a hollow fiber membrane oxygenator (Sorin Monolyth), (2) uses this data to develop a model to predict performance under a wide range of clinical conditions, (3) compares predicted performance with clinical data collected at two open heart centers, and (4) reviews the complexities of comparing laboratory and clinical performance. An in-vitro "oxygenator-deoxygenator" circuit was utilized to determine O2 and CO2 gas exchange, blood path pressure drop, and heat exchanger efficiency at a variety of blood and gas flows, under standard (AAMI) blood inlet conditions: [table: see text] This laboratory performance data was compared to hospital and computer modeling data. Simple numerical comparison and analysis of variance of regression coefficients over groups indicated that some clinical parameters of performance (oxygen transfer and coefficient of heat exchange) were not predicted with the laboratory data. It is concluded that the laboratory performance data determined under strict controlled conditions may be of limited value in predicting clinical performance unless modeled to allow for variances in operating conditions.
منابع مشابه
An in vitro protocol for evaluation and comparison of membrane oxygenators.
With the trend in open heart surgery toward normothermic bypass and warm blood cardioplegia, greater demand is being placed on the perfusionist to select an oxygenator that will perform safely and efficiently under a variety of conditions. While manufacturers report performance parameters for their products, the data is often not comparable due to widely differing conditions. Recent in vitro ...
متن کاملDevelopment of a new hollow fiber silicone membrane oxygenator: in vitro study.
An experimental silicone hollow fiber membrane oxygenator for long-term extracorporeal membrane oxygenation (ECMO) was developed in our laboratory using an ultrathin silicone hollow fiber. However, the marginal gas transfer performances and a high-pressure drop in some cases were demonstrated in the initial models. In order to improve performance the following features were incorporated in the ...
متن کاملA Simplified In Vitro System for Evaluating Gas Transfer Characteristics of Oxygenators
Despite the excellent performance of membrane oxygenators, bubble oxygenators continue to dominate routine open heart surgery. Newer versions with reduced gas:blood flow ratios continue to appear for clinical application 1•2. The new models generally provide data on partial pressure of oxygen (p02) of oxygenated blood at given blood and oxygen flow rates from clinical perfusions37. Clinical dat...
متن کاملProficiency test performance as a predictor of accuracy of routine patient testing for theophylline.
Proficiency testing (PT) is pivotal in assessing laboratory qualifications for certification and licensure. PT is expected to typify routine assay performance and determine whether the laboratory is producing clinically useful test results. Conventional schemes use mail-distributed test specimens and are often criticized as measuring the best possible laboratory performance, principally because...
متن کاملAir Transmission Comparison of the Affinity Fusion Oxygenator with an Integrated Arterial Filter to the Affinity NT Oxygenator with a Separate Arterial Filter.
Arterial filters used in the extracorporeal circuit (ECC) have been shown to minimize cerebral injury by capturing particulate matter and microbubbles. We clinically use the Affinity NT oxygenator with an Affinity arterial filter attached ("Affinity system"). The new Affinity Fusion oxygenator ("Fusion") incorporates integrated arterial filtering. Our aim was to determine if the Fusion oxygenat...