In vitro toxicity and mutagenicity of CoCrMo and Ti6Al wear particles.

نویسندگان

  • A Katzer
  • S Hockertz
  • G H Buchhorn
  • J F Loehr
چکیده

Contact of wear particles with body fluids can result in widespread dissemination of extractable constituents from joint implants. The aim of this in vitro study is to clarify whether there is a mutagenic and/or carcinogenic risk from CoCrMo and Ti6Al wear particles. Particles of a representative size were produced by fretting; toxicity and mutagenicity were investigated using the salmonella/microsome test according to AMES and the V79-HGPRT Test (Chinese Hamster Fibroblasts). To obtain the greatest possible elution of all constituents the metallic wear particles were extracted with dimethylsulfoxyd and water and the resulting eluates mixed together. Neither the bacterial assay nor the mammalian cell system after repeated test series under standardised conditions produced evidence of a toxic or mutagenic effect in the concentration range under study. It is therefore not to be expected that CoCrMo or Ti6Al alloys initiate carcinogenesis in the human organism.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of wear particles of polyether-ether-ketone and cobalt-chromium-molybdenum on CD4- and CD8-T-cell responses

T-cells, second only to macrophages, are often considered as the potential cells involved in debris-related failure of arthroplasty. Here, we assessed the effects of particulate wear debris on T-cells and inflammatory reactions. Blood samples from 25 donors were incubated with polyether-ether-ketone (PEEK) and cobalt-chromium-molybdenum (CoCrMo) particles generated by custom cryo-milling and pu...

متن کامل

Micro- and Nano-scale Tribo-Corrosion of Cast CoCrMo

Previous studies have established that some of the wear damage seen on cast CoCrMo joint surface is caused by entrained third-body hard particles. In this study, wet-cell micro-indentation and nano-scratch tests have been carried out with the direct aim of simulating wear damage induced by single abrasive particles entrained between the surfaces of cast CoCrMo hip implants. In situ electrochemi...

متن کامل

In vitro Wear Rate and Co Ion Release of Compositionally and Structurally Graded CoCrMo-Ti6Al4V Structures.

Novel, unitized structures with porous Ti6Al4V alloy on one side and compositionally graded, hard CoCrMo alloy surface on the other side have been fabricated using laser engineered net shaping (LENS™) process. Gradient structures with 50%, 70% and 86% CoCrMo alloy on the top surface showed high hardness in the range of 615 and 957 HV. The gradient structures were evaluated for their in vitro we...

متن کامل

Wear mapping of CoCrMo alloy in simulated bio-tribocorrosion conditions of a hip prosthesis bearing in calf serum solution.

Wear maps were developed following a series of micro-abrasion-corrosion testing during idealised hip contact conditions for a CoCrMo alloy in a foetal calf serum solution. The main aim of the study was to characterise wear-corrosion or bio-tribocorrosion regimes of the alloy over a range of applied loads and applied potentials. The transitioning micro-abrasion-corrosion mechanisms, synergisms a...

متن کامل

Wear of CoCrMo alloys used in metal-on-metal hip joints A tribocorrosion appraisal

A good biocompatibility, excellent mechanical properties and high corrosion resistance characterize CoCrMo alloys. Therefore they are widely used for artificial joints in biomedical implants. However, the degradation of the implants during service life leads to the release into the body of toxic ions and wear particles. This continuous degradation is of concern for long-term stability of the im...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Toxicology

دوره 190 3  شماره 

صفحات  -

تاریخ انتشار 2003