To fill microelectrodes using backfilling method needs excessive time approximately 4-6 h. It is often difficult to fill microelectrodes without damage or leakage. A main problem is bubble formation in microelectrodes which has an impact on the electrical properties of the electrode and thus it influences the quality of the recording. Based on Archimede's principle there is a force within a solution which pushes insoluble material with a lower specific gravity upward and outside of the solution. Centrifugation can increase the force to eliminate the bubbles. We designed a microelectrode holder to protect microelectrode sensitive tips from mechanical damage due to the gravity tensions; it can help to eliminate the bubbles easily and simultaneously in 10 min or less. The tests were performed for 2000, 4000, and 8000 rpm centrifugation each one for 3, 6 and 12 min duration respectively, it was found that the bubbles were completely eliminated at 8000 rpm for 6-12 min and there were no significant differences for resistance, and the number of leaky or damaged electrodes between the two methods. In the new design of devices, the materials used and the design of the holder are simple and the approach is applicable to many laboratories worldwide.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Rapid coating of glass-capillary microelectrodes for single-electrode voltage-clamp.

The single-electrode voltage-clamp technique requires sharp glass-capillary microelectrodes, whose electrical properties often limit the capabilities of the recording system. Here, we describe a rapid and simple way of coating fine microelectrodes with Dricote and Vaseline that improves their performance during voltage-clamp. The coating prevented clogging of the tips, improved the capacitance ...

متن کامل

Making patch-pipettes and sharp electrodes with a programmable puller.

Glass microelectrodes (also called pipettes) have been a workhorse of electrophysiology for decades. Today, such pipettes are made from glass capillaries using a programmable puller. Such instruments heat the capillary using either a metal filament or a laser and draw out the glass using gravity, a motor or both. Pipettes for patch-clamp recording are formed using only heat and gravity, while s...

متن کامل

Innovative Methodology Long-Term, Multisite, Parallel, In-Cell Recording and Stimulation by an Array of Extracellular Microelectrodes

Hai A, Shappir J, Spira ME. Long-term, multisite, parallel, in-cell recording and stimulation by an array of extracellular microelectrodes. J Neurophysiol 104: 559–568, 2010. First published April 28, 2010; doi:10.1152/jn.00265.2010. Here we report on the development of a novel neuroelectronic interface consisting of an array of noninvasive gold-mushroom-shaped microelectrodes (gM Es) that prac...

متن کامل

Non-biological gene carriers designed for overcoming the major extra- and intracellular hurdles in gene delivery, an updated review

Gene therapy as a modern therapeutic approach has not yet advanced to a globally-approved therapeutic approach. Lack of adequate reliable gene delivery system seems to be one of the major reasons from the pharmaceutical biotechnology point of view. Main obstacles delaying successful application of human gene therapy are presented in this review. The unique advantages of non-biological gene carr...

متن کامل

Long-term, multisite, parallel, in-cell recording and stimulation by an array of extracellular microelectrodes.

Here we report on the development of a novel neuroelectronic interface consisting of an array of noninvasive gold-mushroom-shaped microelectrodes (gMmicroEs) that practically provide intracellular recordings and stimulation of many individual neurons, while the electrodes maintain an extracellular position. The development of this interface allows simultaneous, multisite, long-term recordings o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biochemical and biophysical methods

دوره 70 6  شماره 

صفحات  -

تاریخ انتشار 2008