Carpal bone kinematics and ligament lengthening studied for the full range of joint movement.

نویسندگان

  • H H Savelberg
  • J D Otten
  • J G Kooloos
  • R Huiskes
  • J M Kauer
چکیده

Present data on carpal kinematics and carpal ligament behaviour are limited to flexion and deviation movements of the hand. These motions do not represent all the wrist-joint motions which are important for the activities of daily living. The goal of this project was to obtain insight into carpal kinematics and carpal ligament behaviour during motions of the hand covering the full range of motion of the wrist joint. The carpals and the ligaments of four wrist-joint specimens were provided with radiopaque markers. These joints were subjected to Röntgenstereophotogrammetric experimentation in a large number of hand positions to determine carpal positions and ligament lengths. The movements of the carpal bones were described by means of finite helical axes (FHA). It was found that the movements of the carpals in the distal row closely resemble those of the hand. Conversely, the motions of the carpals of the proximal row appeared not to be directly proportional to the hand motions and exhibited clear out-of-plane movements. Furthermore, it could be shown that movements of the hand into the ulnodorsal quadrant of the full range of hand motion corresponds to larger helical rotations and translations for most of the carpals than when the hand was moved into any other quadrant. The maximal ligament length changes determined did not exceed the length changes reported for pure flexion and pure deviation movements of the hand.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Human carpal ligament recruitment and three-dimensional carpal motion.

In five fresh human cadaver wrist joints six carpal ligaments and seven carpal bones were marked with small, radio-opaque pellets. Using a roentgenstereophotogrammetric measuring system, the ligamentous length changes and the kinematics of carpal bones were determined in different flexion and deviation positions of the hand. The data generated by this method differ significantly from lengthenin...

متن کامل

A Comparison of Hand Pain and Hand Function after Z-plasty Reconstruction of the Transverse Carpal Ligament with Traditional Median Neurolysis in Carpal Tunnel Syndrome

       Background: Carpal tunnel syndrome is the most common focal mono-neuropathy. A study was designed to compare the effects of traditional open carpal tunnel release with median neurolysis and Z-plasty reconstruction of the transverse carpal ligament on post-operative hand pain and hand function in patients with idiopathic carpal tunnel syndrome.   Methods: Fifty-two patients with idiopathi...

متن کامل

In-vivo three-dimensional carpal bone kinematics during flexion-extension and radio-ulnar deviation of the wrist: Dynamic motion versus step-wise static wrist positions.

An in-vivo approach to the measurement of three-dimensional motion patterns of carpal bones in the wrist may have future diagnostic applications, particularly for ligament injuries of the wrist. Static methods to measure carpal kinematics in-vivo only provide an approximation of the true kinematics of the carpal bones. This study is aimed at finding the difference between dynamically and static...

متن کامل

Percutaneous Versus Open Hamstring Lengthening in Spastic Diplegic Cerebral Palsy

Background: Open hamstring lengthening (oHSL) is commonly performed to decrease knee contracture and improvegait and posture for children with spastic diplegia. Furthermore, percutaneous hamstring lengthening (pHSL) is alsogaining popularity as an alternative to the open approach. This study aimed to compare the results of pHSL versusoHSL and to determine the efficacy and safe...

متن کامل

Three-Dimensional Carpal Kinematics after Carpal Tunnel Release.

BACKGROUND Carpal tunnel release (CTR) has been shown to change carpal arch morphology. However, the effect of CTR on the three-dimensional kinematics of the carpal bones has not been demonstrated. PURPOSE This study examined whether release of the transverse carpal ligament (TCL) would alter the three-dimensional kinematics of the carpus, specifically the bony attachments of the TCL. METHO...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of biomechanics

دوره 26 12  شماره 

صفحات  -

تاریخ انتشار 1993