Designing Low Frequency I.c Filter Using Pseudo Resistor for Biopotential Measurments
نویسنده
چکیده
Standard medical diagnosis requires attaching sensors or electrodes to the patient and then connecting these electrodes to bulky equipment powered by mains supply. This is usually an acceptable procedure for short term patient monitoring. However, for long term monitoring, this approach is neither comfortable nor durable. Therefore considering fully implantable electronic systems which have many useful applications including monitoring cardiac irregularities in pacemaker systems, are the preferred. This thesis intends to show the design of low frequency IC filters. Given that large time constants are required in low cutoff frequency filter designs, various approaches can be utilized to provide large values of resistors or capacitors. To demonstrate the proposed method, third order low-pass and high-pass filters for ECG signals with cutoff frequencies in range of 0.1-100 Hz are implemented. Butterworth topology is used in both filter designs to preserve the morphological information of the ECG signals.
منابع مشابه
A Novel Structure for Realization of a Pseudo Two Path Band-Pass Filter
In this paper, a modified auto zeroed integrator is used to design and simulate a low-voltage high-Q switched capacitor pseudo 2-path filter. The filter is a sixth–order Chebyshev band-pass filter operating at sampling frequency of 1MHz and center frequency of 250 kHz with a quality factor of 50. The proposed filter has both low-voltage and high speed properties of the auto zeroed integrators ...
متن کاملLow latency IIR digital filter design by using metaheuristic optimization algorithms
Filters are particularly important class of LTI systems. Digital filters have great impact on modern signal processing due to their programmability, reusability, and capacity to reduce noise to a satisfactory level. From the past few decades, IIR digital filter design is an important research field. Design of an IIR digital filter with desired specifications leads to a no convex optimization pr...
متن کاملMicrocontroller-based Biopotential Data Acquisition Systems: Practical Design Considerations
Non-invasive bioimpedance measurements are an important part of routine diagnostic procedures. ECG (Electrocardiograph), EEG (Electroencephalograph), EMG (Electromyography) and EOG (Electrooculograph) measurements are amongst the most common non-invasive measurements used for diagnosis. The advances in microcontroller technology over the past 25 years have resulted in general-purpose, low-cost,...
متن کاملSwitched-Resistor Filters-A Continuous Time Approach to Monolithic MOS Filter Design
Absfruct-A method of designing continuous-time active RC filters which employ only capacitors and FET transistors is presentedl. The effective RC time constants of these filters are determined by capacitor ratios. The filters employ switched resistors. These filters can uric any existing active RC or passive RC topology as the basis for the design and inherit the sensitivity properties of the c...
متن کاملA MEMS Capacitive Microphone Modelling for Integrated Circuits
In this paper, a model for MEMS capacitive microphone is presented for integrated circuits. The microphone has a diaphragm thickness of 1 μm, 0.5 × 0.5 mm2 dimension, and an air gap of 1.0 μm. Using the analytical and simulation results, the important features of MEMS capacitive microphone such as pull-in voltage and sensitivity are obtained 3.8v and 6.916 mV/Pa, respectively while there is no...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2011