The effect of a range of disinfectants on the dimensional accuracy and stability of some impression materials.

نویسندگان

  • D C Jagger
  • R W Vowles
  • L McNally
  • F Davis
  • D J O'Sullivan
چکیده

Disinfection of dental impressions should be considered as a routine procedure in dental surgeries and dental laboratories. Disinfectants can have deleterious effects on some properties of impression materials. The aim of this study was to evaluate the dimensional accuracy and dimensional stability of a model dental stone, reproduced from five commonly used impression materials (Aquasil soft putty/Aquasil Ultra LV; Aquasil Monophase; Aquasil Ultra Heavy; Impregum F and Provil putty/Provil Light CD wash) retained by their adhesives in acrylic resin trays and exposed to three disinfectant solutions (Perform ID; Haz-Tabs and MD 520). Two hundred models were used to investigate the effect of the three disinfectants on the dimensional accuracy of the five impression materials. Five impressions were taken for each impression material for each disinfection treatment group. Measurements were carried out using a High Precision Reflex Microscope. All materials demonstrated a percentage change in dimensions when subjected to no disinfection when compared to the brass master die and all materials demonstrated a percentage change in dimension when subjected to the different disinfection procedures. The results of this study have demonstrated that for all of the materials investigated, the changes in dimensional stability were small in the order of microns. These changes may however be of clinical significance for procedures requiring a high degree of accuracy, for example fixed prosthodontics. The materials respond differently depending on the disinfectant used and it may therefore be appropriate that manufacturers recommend the use of particular disinfectants for their products in order to ensure optimum dimensional accuracy and stability.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effect of Three Disinfectants on Dimensional Changes of Different Impression Materials

Background and Aim: Disinfection of dental impression materials can alter their dimensional stability, which in turn can affect the accuracy of dental casts. This study aimed to determine the effect of three disinfectants on the dimensional changes of ir-reversible hydrocolloid impression materials and addition silicones. Materials and Methods: Forty alginate and 40 addition silicone impressio...

متن کامل

Comparative Study of the Effect of Storage Environment Temperature on the Accuracy of Hygedent and Chromogel Alginate Impression Materials

Background and Aim: Considering the lack of sufficient and even contradictory studies on the effect of temperature-dependent dimensional changes of alginate before pouring, this study aimed to investigate the effect of storage temperature of Hygedent and Chromogel alginate molds on dimensional stability.  Materials and Methods: In this in-vitro experimental study, dimensional changes of two t...

متن کامل

A comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil)

A comparison of the accuracy and dimensional stability between two silicon impression materials (Speedex and Irasil) Dr. M. Sabouhi* - Dr. M. Dakhilalian** - Dr. N. Nehchiri*** *- Assistant Professor of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Sciences. **- Member of Fixed Prosthodontics Dept. - Faculty of Dentistry – Isfahan University of Medical Scienc...

متن کامل

Effects of Water/Powder Ratio of Irreversible Hydrocolloid on Dimensional Stability of Impressions

Background and Aim: Water/powder ratio is effective on some properties of irreversible hydrocolloid impression materials. This study aimed to determine the ef-fects of water/powder ratio of irreversible hydrocolloid impression materials on di-mensional stability of impressions. Materials and Methods: In this in vitro experimental study, a metal model with two abutments as anchoring support for...

متن کامل

Dimensional accuracy of three impression materials by one-step and two-step impression techniques: An in vitro study

Introduction: An accurate impression is essential to create a well-fitted dental prosthesis. This study aimed to compare the dimensional accuracy of three elastomeric materials using one-step and two-step impression techniques. Methods: In this study, 20 impressions were fabricated for each Vinyl siloxane ether (Identium), condensation silicone (Speedex), and a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The European journal of prosthodontics and restorative dentistry

دوره 15 1  شماره 

صفحات  -

تاریخ انتشار 2007