Complications of invasive monitoring.

نویسنده

  • T Andrew Bowdle
چکیده

Invasive monitoring in anesthesiology is relatively safe. Arterial catheterization in particular has an extremely low rate of serious complications. Radial, brachial, and femoral artery catheterization sites appear to have similar and low complication rates. CVP and PA catheters are more dangerous and entail potentially fatal complications. The most troublesome complication with CVP catheters is perforation of the heart or cava, which should be avoidable under most circumstances if care is taken to position the catheter properly, outside the heart. Chest radiography should be used to specifically ascertain that the catheter is not in a dangerous location. The most troublesome complication with PA catheters is perforation of the pulmonary artery. This is probably a sporadic problem, and it is not necessarily avoidable by adherence to particular techniques. It should be assumed that hemoptysis in a patient with a PA catheter is caused by perforation of the pulmonary artery until proven otherwise, and it should be treated aggressively.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Non-invasive Optical Techniques for determination of blood Glucose levels: A Review Article

This article reviews the development of non-invasive optical techniques for determination of blood glucose concentrations in diabetic patients. Early diagnosis and daily management are essential for ensuring the healthy life of diabetic patients. The determination of blood glucose concentration with common devices involves the chemical analysis of blood samples, which are obtained by pricking t...

متن کامل

Complications to invasive epilepsy surgery workup with subdural and depth electrodes: a prospective population-based observational study

OBJECTIVE In some patients who undergo presurgical workup for drug-resistant epilepsy invasive seizure monitoring is needed to define the seizure onset zone and delineate eloquent cortex. Such procedures carry risks for complications causing permanent morbidity and even mortality. In this study, prospective data on complications in a national population-based sample were analysed. DESIGN Comp...

متن کامل

A Study of Continuous Blood Glucose Monitoring Using Non Invasive Technique

The advent of a pain free non-invasive technology would improve the patient’s compliance for regular blood glucose monitoring. Subsequently the diabetic patient’s life will improve considerably. Glucose monitoring is an integral part of diabetes management, and the maintenance of physiological blood glucose concentration is the only way for a diabetic to avoid life-threatening diabetic complica...

متن کامل

Minimally Invasive Surgical Approach to Distal Fibula Fractures: A Technique Tip

  Wound complications following ankle fracture surgery are a major concern. Through the use of minimally invasive surgical techniques some of these complications can be mitigated. Recent investigations have reported on percutaneous fixation of distal fibula fractures demonstrating similar radiographic and functional outcomes to traditional open approaches. The purpose of this manuscript is to ...

متن کامل

Diagnosis and Rescue of a Kinked Pulmonary Artery Catheter

Invasive hemodynamic monitoring with a pulmonary catheter has been relatively routine in cardiovascular and complex surgical operations as well as in the management of critical illnesses. However, due to multiple potential complications and its invasive nature, its use has decreased over the years and less invasive methods such as transesophageal echocardiography and hemodynamic sensors have ga...

متن کامل

مانیتورینگ همودینامیک به روش غیر تهاجمی در بخش مراقبت های ویژه: مقاله مروری

Aim and background : Hemodynamic monitoring of critical patients in intensive units is the cornstone of care. It constitutes an extensive part of care and is helpful in determination of the causes and the response to treatment of hemodynamic instability. Aim of this review articale is to investigate of the Non invasive hemodynamic monitoring in critical care units. Materials and Methods:61 art...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Anesthesiology clinics of North America

دوره 20 3  شماره 

صفحات  -

تاریخ انتشار 2002