Design, simulation, and evaluation of imaging oximeters

نویسندگان

  • Steve Dai
  • Ye Tian
  • Joyce E. Farrell
چکیده

Computer simulations have played an important role in the design and evaluation of imaging sensors with applications in remote sensing [1] and consumer photography [2-7]. In this paper, we provide an example of computer simulations used to guide the design of imaging sensors for a biomedical application: We consider how sensor design, illumination, measurement geometry, and skin type influence the ability to detect blood oxygen saturation from non-invasive measurements of skin reflectance. The methodology we describe in this paper can be used to design, simulate and evaluate the design of other biomedical imaging systems.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of X-ray absorbed dose in thyroid during CXR imaging of the chest by Monte Carlo simulation (DOSXYZnrc)

Abstract:   Introduction: Chest radiography is one of the most common X-ray imaging procedures performed worldwide. During this process, in addition to the chest, other tissues, including the thyroid, are also exposed to radiation. Due to the fact that one of the most important risk factors for thyroid cancer is ionizing radiation, measuring the absorption of X- rays in the thyroid is of spec...

متن کامل

Design and performance evaluation of spheroid geometry for brain PET scanner using Monte Carlo modeling

Introduction: There has been a curiosity about the spheroid geometry for PET scanners developments since several years ago, therefore in this study, we are aiming to evaluate the performance of this geometry and compare its performance with cylindrical geometry using Monte Carlo simulation. Methods: We simulated a spheroid geometry with a radius of 199 mm...

متن کامل

Evaluation of the performance of parallel-hole collimator for high resolution small animal SPECT: A Monte Carlo study

Introduction: Image quality and accuracy of in vivo activity quantification in SPECT are affected by collimator penetration and scatter components, especially in high energy imaging. These phenomena highly depend on the collimator characteristic and photon energy. The presence of penetrated and scattered photons from collimator in SPECT images degrades spatial resolution, contr...

متن کامل

Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...

متن کامل

Quadrature Amplitude Modulated Digital Radio Transmission Modeling and Simulation

Computer aided design and computer aided modeling tools are becoming increasingly important in the design and performance evaluation of communication systems. In this work, we report on the computer simulation modeling study of terrestrial digital microwave radio transmission, using Block Oriented System Simulator package (BOSS). The work concentrates on semi-analytical error rate evaluation in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013