Safety of and tolerance to adenosine infusion for myocardial perfusion single-photon emission computed tomography in a Japanese population.

نویسندگان

  • Kunihiko Hatanaka
  • Masayuki Doi
  • Satoshi Hirohata
  • Shigeshi Kamikawa
  • Yoko Kaji
  • Tsutomu Katoh
  • Shozo Kusachi
  • Yoshifumi Ninomiya
  • Tohru Ohe
چکیده

BACKGROUND Adenosine has been available for use in myocardial perfusion single-photon emission computed tomography (SPECT) in Japan since 2005. The purpose of this study was to evaluate the safety of and tolerance to thallium-201 myocardial perfusion SPECT with intravenous adenosine infusion in Japanese patients with suspected coronary artery disease. METHODS AND RESULTS Two hundred and six consecutive patients who underwent an adenosine infusion (120 mug . kg(-1) . min(-1)) SPECT at Sumitomo Besshi Hospital (Niihama, Japan) were investigated. The effects of adenosine infusion were monitored for each patient. A coronary angiography was performed in 81 patients. Adenosine infusion significantly decreased blood pressure and increased heart rate. Adverse reactions were observed in 161 patients (78.2%). Most reactions were transient, disappearing soon after the termination of adenosine infusion. No serious adverse reactions, such as acute myocardial infarction or death, occurred. Adenosine infusion was terminated in 3 patients (1.5%) because of near syncope or sustained 2:1 atrioventricular block. Electrocardiographic changes occurred in 15 patients (7.3%). Self-assessed scoring after SPECT showed that the patients were very tolerant (74.6% of 177 patients) of adenosine infusion myocardial SPECT. The sensitivity and specificity were 75.0% and 69.7%, respectively. CONCLUSIONS Adenosine infusion myocardial SPECT is safe and well tolerated in the Japanese population, despite the frequent occurrence of minor adverse reactions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Prediction of Changes in Left Ventricular Ejection Fraction after Off-Pump Coronary Artery Bypass Grafting Surgery by Myocardial Perfusion Single-Photon Emission Computed Tomography

Introduction: Left ventricular ejection fraction (LVEF) is considered to be the single most important prognostic factor in patients with previous myocardial infarction. LVEF is not improved in all patients after coronary artery bypass grafting (CABG). This study aimed to assess the possibility of prediction of LVEF changes after CABG using myocardial perfusion gated signle photon emission compu...

متن کامل

Evaluation of myocardial perfusion and function after kidney transplantation by Gated SPECT myocardial perfusion scintigraphy

Introduction: The aim of this study was to evaluate the effect of successful kidney transplantation (KT) on myocardial perfusion and left ventricular function by both qualitative (visual) interpretation and semiquantitative parameters, using myocardial perfusion scintigraphy with gated-single photon emission computed tomography (gated-SPECT) in patients suffering from end-stage renal disease. ...

متن کامل

Adenosine myocardial SPECT--its efficacy and safety and correlation with coronary angiogram.

OBJECTIVE The aim of this study was to determine the safety and efficacy of adenosine Tc99m sestamibi myocardial perfusion study under controlled conditions and to correlate the adenosine Tc99m sestamibi perfusion defects and the coronary angiography in patients investigated for coronary artery disease. METHODS This prospective study included 122 consecutive patients who underwent adenosine T...

متن کامل

Effects of depression on myocardial perfusion scintigraphy [Persian]

  Introduction: The relationship between depression and coronary artery disease is well established; however assessment of this relationship using functional and semi-quantitative imaging (myocardial perfusion scintigraphy) was lacking. The aim of this study was to assess the relationship between the severity of depression and the severity of myocardial perfusion abno...

متن کامل

Improvement of diagnostic accuracy of Parkinson's disease on I-123-ioflupane single photon emission computed tomography (123I FP-CIT SPECT) using new Japanese normal database

Objective(s): I-123-ioflupane single photon emission computed tomography (FP-CIT-SPECT) has been used to assess dopamine transporter (DAT) loss in Parkinson's disease. The specific binding ratio (SBR), a quantitative parameter of DAT density in the striatum, may be affected by differences in age, sex, and SPECT system. The purpose of this study was to evaluate the util...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Circulation journal : official journal of the Japanese Circulation Society

دوره 71 6  شماره 

صفحات  -

تاریخ انتشار 2007