Fully automatic detection of deep white matter T1 hypointense lesions in multiple sclerosis.

نویسندگان

  • Lothar Spies
  • Anja Tewes
  • Per Suppa
  • Roland Opfer
  • Ralph Buchert
  • Gerhard Winkler
  • Alaleh Raji
چکیده

A novel method is presented for fully automatic detection of candidate white matter (WM) T1 hypointense lesions in three-dimensional high-resolution T1-weighted magnetic resonance (MR) images. By definition, T1 hypointense lesions have similar intensity as gray matter (GM) and thus appear darker than surrounding normal WM in T1-weighted images. The novel method uses a standard classification algorithm to partition T1-weighted images into GM, WM and cerebrospinal fluid (CSF). As a consequence, T1 hypointense lesions are assigned an increased GM probability by the standard classification algorithm. The GM component image of a patient is then tested voxel-by-voxel against GM component images of a normative database of healthy individuals. Clusters (≥0.1 ml) of significantly increased GM density within a predefined mask of deep WM are defined as lesions. The performance of the algorithm was assessed on voxel level by a simulation study. A maximum dice similarity coefficient of 60% was found for a typical T1 lesion pattern with contrasts ranging from WM to cortical GM, indicating substantial agreement between ground truth and automatic detection. Retrospective application to 10 patients with multiple sclerosis demonstrated that 93 out of 96 T1 hypointense lesions were detected. On average 3.6 false positive T1 hypointense lesions per patient were found. The novel method is promising to support the detection of hypointense lesions in T1-weighted images which warrants further evaluation in larger patient samples.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Characterization of multiple sclerosis plaques with T1-weighted MR and quantitative magnetization transfer.

PURPOSE To investigate the relationship between the appearance of multiple sclerosis lesions identified on unenhanced T1-weighted images and their corresponding magnetization transfer ratios. METHODS A total of 119 white matter lesions seen on T2-weighted images in 17 patients with multiple sclerosis were evaluated. Axial T1-weighted images were used to classify the lesions as isointense to w...

متن کامل

The Assessment of Structural Changes in MS Plaques and Normal Appearing White Matter Using Quantitative Magnetization Transfer Imaging (MTI)

Introduction: Multiple sclerosis (MS) is a demyelinating disease of the central nervous system (CNS), affecting mostly young people at a mean age of 30 years. Magnetic resonance imaging (MRI) is one of the most specific and sensitive methods in diagnosing and detecting the evolution of multiple sclerosis disease. But it does not have the ability to differentiate between distinct histopathologic...

متن کامل

Patterns of lesion development in multiple sclerosis: longitudinal observations with T1-weighted spin-echo and magnetization transfer MR.

PURPOSE We evaluated the appearance of enhancing multiple sclerosis (MS) lesions on unenhanced T1-weighted MR images and the natural course of enhancing MS lesions on serial unenhanced T1-weighted and magnetization transfer (MT) MR images. METHODS One hundred twenty-six enhancing lesions were followed up monthly for 6 to 12 months to determine their signal intensity on unenhanced T1-weighted ...

متن کامل

Large, nonplateauing relationship between clinical disability and cerebral white matter lesion load in patients with multiple sclerosis.

OBJECTIVE To better characterize the relationship between cerebral white matter lesion load (CWM-LL) and clinical disability by (1) covering the entire range of the Kurtzke Expanded Disability Status Scale (EDSS), (2) minimizing nonbiological sources of variability, and (3) increasing pathologic specificity by studying CWM lesions that are hypointense on T1-weighted magnetic resonance imaging. ...

متن کامل

Lesion heterogeneity in multiple sclerosis: a study of the relations between appearances on T1 weighted images, T1 relaxation times, and metabolite concentrations.

OBJECTIVES Multiple sclerosis lesions appear as areas of high signal on T2 weighted MRI. A proportion of these lesions, when viewed on T1 weighted MRI, appear hypointense compared with surrounding white matter. These hypointense T1 lesions are thought to represent areas of greater tissue damage compared with the more non-specific, total T2 lesion load. This study aimed to better characterise th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Physics in medicine and biology

دوره 58 23  شماره 

صفحات  -

تاریخ انتشار 2013