Ion channel pharmacology under flow: automation via well-plate microfluidics.

نویسندگان

  • C Ian Spencer
  • Nianzhen Li
  • Qin Chen
  • Juliette Johnson
  • Tanner Nevill
  • Juha Kammonen
  • Cristian Ionescu-Zanetti
چکیده

Automated patch clamping addresses the need for high-throughput screening of chemical entities that alter ion channel function. As a result, there is considerable utility in the pharmaceutical screening arena for novel platforms that can produce relevant data both rapidly and consistently. Here we present results that were obtained with an innovative microfluidic automated patch clamp system utilizing a well-plate that eliminates the necessity of internal robotic liquid handling. Continuous recording from cell ensembles, rapid solution switching, and a bench-top footprint enable a number of assay formats previously inaccessible to automated systems. An electro-pneumatic interface was employed to drive the laminar flow of solutions in a microfluidic network that delivered cells in suspension to ensemble recording sites. Whole-cell voltage clamp was applied to linear arrays of 20 cells in parallel utilizing a 64-channel voltage clamp amplifier. A number of unique assays requiring sequential compound applications separated by a second or less, such as rapid determination of the agonist EC(50) for a ligand-gated ion channel or the kinetics of desensitization recovery, are enabled by the system. In addition, the system was validated via electrophysiological characterizations of both voltage-gated and ligand-gated ion channel targets: hK(V)2.1 and human Ether-à-go-go-related gene potassium channels, hNa(V)1.7 and 1.8 sodium channels, and (α1) hGABA(A) and (α1) human nicotinic acetylcholine receptor receptors. Our results show that the voltage dependence, kinetics, and interactions of these channels with pharmacological agents were matched to reference data. The results from these IonFlux™ experiments demonstrate that the system provides high-throughput automated electrophysiology with enhanced reliability and consistency, in a user-friendly format.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Effects of Hall current and ion-slip on unsteady hydromagnetic generalised Couette flow in a rotating Darcian channel

Unsteady hydromagnetic generalised Couette flow of a viscous, incompressible and electrically conducting fluid between two horizontal parallel porous plates Darcian channel in the presence of a uniform transverse magnetic field taking Hall current and ion-slip into account in a rotating system is investigated. An exact solution of the governing equations is obtained by Laplace transform techniq...

متن کامل

Flow Shear Stress Enhances the Proliferative Potential of Cultured Radial Glial Cells Possibly Via an Activation of Mechanosensitive Calcium Channel

Radial glial cells (RGCs) which function as neural stem cells are known to be non-excitable and their proliferation depends on the intracellular calcium (Ca2+) level. It has been well established that Inositol 1,4,5-trisphosphate (IP3)-mediated Ca2+ release and Ca2+ entry through various Ca2+ channels are involved in the proliferation of RGCs. Furthermore, RGCs line the ventricular wall and are...

متن کامل

Recent Advancements towards Full-System Microfluidics

Microfluidics is quickly becoming a key technology in an expanding range of fields, such as medical sciences, biosensing, bioactuation, chemical synthesis, and more. This is helping its transformation from a promising R&D tool to commercially viable technology. Fuelling this expansion is the intensified focus on automation and enhanced functionality through integration of complex electrical...

متن کامل

Time-periodic Electroosmotic Flow of Non-newtonian Fluids in Microchannels

The alternating current electroosmotic flow of a non-Newtonian power-law fluid is studied in a circular microchannel. A numerical method is employed to solve the non-linear Poisson-Boltzmann and the momentum equations. The main parameters which affect the flow field are the flow behavior index, the dimensionless zeta potential and the dimensionless frequency. At very low dimensionless frequenci...

متن کامل

Deformation of a single mouse oocyte in a constricted microfluidic channel.

Single oocyte manipulation in microfluidic channels via precisely controlled flow is critical in microfluidic-based in vitro fertilization. Such systems can potentially minimize the number of transfer steps among containers for rinsing as often performed during conventional in vitro fertilization and can standardize protocols by minimizing manual handling steps. To study shape deformation of oo...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Assay and drug development technologies

دوره 10 4  شماره 

صفحات  -

تاریخ انتشار 2012