A Summary of Beamline Operations with the A1200
نویسنده
چکیده
1998 marked the last full year of operation with the A1200 fragment separator as part of the high-energy beam line system. Logs of this year show 80 beamline tunes of primary beam and 40 secondary beams, but not all such tunes were considered interesting enough to record. A one-word description of these activities is “routine”. What follows is a brief history of what was done to achieve routine operation. In 1991, beamline tunes were done essentially by hand with minimal software assistance. (An exception to this was the program “BOSS”, which controlled only the A1200 beamline segments). Predictions of optics codes were not in routine use and the principal tuning parameter was a “small spot” on the viewers. Long setup times (as long as 24 hours) and difficulty achieving the desired conditions on the experimental target indicated another approach was needed. A process was begun t o correct this situation, including the following measures:
منابع مشابه
Designing an approprate solenoid and magnetic field for the HZDR laser-driven beamline
Nowadays, due to the high costs and large dimensions of the conventional proton accelerators, other optimal methods for producing the proton beam have been studied. Using of Laser-driven proton accelerators is one of the important and new methods. In laser-driven ion acceleration, a highly ultra-intense laser pulse interacts with solid density targets and will create a plasma media that will ac...
متن کاملThe Development of the GCPCC Protein Crystallography Beamline at CAMD
The Gulf Coast Protein Crystallography Consortium (GCPCC) is developing a beamline at the LSU/CAMD synchrotron. This beamline will be capable of standard macromolecular multiple-wavelength anomalous diffraction (MAD) phasing experiments over an energy range of 7-17.5 keV. The optical configuration uses a vertical collimating mirror, a channel-cut Si (111) monochromator and a focusing toroidal m...
متن کاملA Second Beam-diagnostic Beamline for the Advanced Light Source*
A second beamline, BL 7.2, completely dedicated to beam diagnostics is being installed at the Advanced Light Source (ALS). The design has been optimized for the measurement of the momentum spread and emittance of the stored beam in combination with the existing diagnostic beamline, BL 3.1. A detailed analysis of the experimental error has allowed the definition of the system parameters. The obt...
متن کاملخطوط باریکه چشمه نور ایران
This paper describes day-one beamlines of the Iranian Light Source Facility and design concept of powder diffraction and spectromicroscopy beamlines as the most priorities of each synchrotron that cover the research requirements in the fields of physics, chemistry, nano-science, etc. For powder diffraction beamline energy range is 6-30 keV, resolution: 10-4, flux: 1012(ph/s/0.1%B.W.) and spot s...
متن کاملبررسی روایی و پایایی نسخۀ فارسی پرسشنامۀIKDCبرای ارزیابی وضعیت بیماران ایرانی، پس از جراحی رباط صلیبی قدامی و منیسک زانو
Objective: To translate and evaluate the test-retest reliability, internal consistency and construct validity of the Persian version of the IKDC questionnaire in Iranian patients after ACL and meniscal operations. Materials & Methods: After translation based on the Quality Of Life Assessment protocol, the IKDC, KOOS and SF-36 Health Survey were administered to a sample of 101 patients underw...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 1999