Thermal spread of vessel-sealing devices evaluated in a clinically relevant in vitro model.

نویسندگان

  • Daniel Eberli
  • Lukas J Hefermehl
  • Alexander Müller
  • Tullio Sulser
  • Hartmut Knönagel
چکیده

INTRODUCTION Bipolar vessel-sealing devices (VSDs) have advantages in urological surgeries (less hemorrhage, shorter operating time). However, these instruments can cause thermal injuries, which can result in neural damage and necrosis. The objectives of this study were to establish a reproducible in vitro model for standardized assessment of electrosurgical devices and to evaluate whether optimized placement of surgical instruments can reduce the thermal spread. METHODS We evaluated thermal spread of two VSDs in vitro using thin bovine muscle strips. Thermal injury was measured using an infrared camera, temperature probes and histology. The recordings were made with the VSD alone and with a rectangular clamp next to the VSD. RESULTS Both instruments showed a significant temperature spread of 2.5 mm lateral to the VSD. The placement of a metal clamp next to the VSD significantly reduced the temperature spread. Histological examinations were able to underline these findings. CONCLUSIONS In this study we describe a straightforward clinically relevant in vitro model for the evaluation of future electrosurgical instruments. We demonstrated that the thermal spread of VSD could be further reduced by optimized placement of an additional surgical instrument. Our results could help surgeons protect sensitive structures like nerves in the vicinity of the VSD.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Validation of a Laparoscopic Ferromagnetic Technology-based Vessel Sealing Device and Comparative Study to Ultrasonic and Bipolar Laparoscopic Devices

INTRODUCTION Ferromagnetic heating is a new electrosurgery energy modality that has proven effective in hemostatic tissue dissection as well as sealing and dividing blood vessels and vascularized tissue. The purpose of this study was to evaluate a ferromagnetic-based laparoscopic vessel sealing device with respect to sealing and dividing vessels and vascularized tissue and to compare performanc...

متن کامل

COmPARISON Of LAtERAL thERmAL SPREAd uSING mONOPOLAR ANd bIPOLAR dIAthERmy, ANd thE bIPOLAR vESSEL SEALING SyStEm thERmOStAPLERtm duRING thyROIdECtOmy*

Electric devices enabling the maintenance of haemostasis during surgery have found application in modern thyroidectomy procedures. The haemostatic effect is associated with generation of heat, which apart from the intended result may bring about thermal tissue injury. the aim of the study was to determine the thermal spread around the active tip of electric devices in the operating field during...

متن کامل

Comparison of lateral thermal spread using monopolar and bipolar diathermy, and the bipolar vessel sealing system ThermoStapler™ during thyroidectomy.

UNLABELLED Electric devices enabling the maintenance of haemostasis during surgery have found application in modern thyroidectomy procedures. The haemostatic effect is associated with generation of heat, which apart from the intended result may bring about thermal tissue injury. The aim of the study was to determine the thermal spread around the active tip of electric devices in the operating f...

متن کامل

In silico evaluation of geometry variations with respect to the thermal spread during coagulation of egg white using bipolar vessel sealing instruments

BACKGROUND Bipolar vessel sealing is an efficient electrosurgical procedure for the occlusion of blood vessels particularly during minimally invasive surgery. Reliable knowledge of the thermal spread is crucial for a safe application of bipolar vessel sealing instruments when operating close to thermo-sensitive structures, such as nerves. The evolution of the thermal spread over time and space ...

متن کامل

Rapid sealing and cutting of porcine blood vessels, ex vivo, using a high-power, 1470-nm diode laser.

Suture ligation with subsequent cutting of blood vessels to maintain hemostasis during surgery is time consuming and skill intensive. Energy-based electrosurgical and ultrasonic devices are often used to replace sutures and mechanical clips to provide rapid hemostasis and decrease surgery time. Some of these devices may create undesirably large collateral zones of thermal damage and tissue necr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Urologia internationalis

دوره 86 4  شماره 

صفحات  -