Stability of small pegs for cementless implant fixation
نویسندگان
چکیده
Most glenoid implants rely on large centrally located fixation features to avoid perforation of the glenoid vault in its peripheral regions. Upon revision of such components there may not be enough bone left for the reinsertion of an anatomical prosthesis. Multiple press-fit small pegs would allow for less bone resection and strong anchoring in the stiffer and denser peripheral subchondral bone. This study assessed the fixation characteristics, measured as the push-in (Pin ) and pull-out (Pout ) forces, and spring-back, measured as the elastic displacement immediately after insertion, for five different small press-fitted peg configurations manufactured out of UHMWPE cylinders (5 mm diameter and length). A total of 16 specimens for each configuration were tested in two types of solid bone substitute: Hard (40 PCF, 0.64 g/cm3 , worst-case scenario of Pin ) and soft (15 PCF, 0.24 g/cm3 , worst-case scenario of spring-back and Pout ). Two different diametric interference-fits were studied. Geometries with lower stiffness fins (large length to width aspect ratio) were the best performing designs in terms of primary fixation stability. They required the lowest force to fully seat, meaning they are less damaging to the bone during implantation, while providing the highest Pout /Pin ratio, indicating that when implanted they provide the strongest anchoring for the glenoid component. It is highlighted that drilling of chamfered holes could minimize spring-back displacements. These findings are relevant for the design of implants press-fitted pegs because primary fixation has been shown to be an important factor in achieving osseointegration and longevity of secondary fixation. © 2017 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:2765-2772, 2017.
منابع مشابه
•The Effect of Peg vs. Keel Fixation on Micromotion of Cementless Tibial Baseplates
INTRODUCTION: Initial implant stability is crucial to cementless knee replacement success, however the optimal design remains elusive. Previous biomechanical studies have aimed at quantifying initial stability using simplified loading scenarios. The objective of this study was to use a physiological relevant methodology which incorporates torsion, shear and compression forces to evaluate tibial...
متن کاملImplant Design in Cementless Hip Arthroplasty
When performing cementless hip arthroplasty, it is critical to achieve firm primary mechanical stability followed by biological fixation. In order to achieve this, it is essential to fully understand characteristics of implant design. In this review, the authors review fixation principles for a variety of implants used for cementless hip replacement and considerations for making an optimal sele...
متن کاملInfluence of cementless cup surface on stability and bone fixation 2 years after total hip arthroplasty.
Loss of fixation between bone and implant surface is one of the main treatment problems in total hip arthroplasty. It might lead to implant instability, bone loss and treatment failure resulting in revision surgery. Surface modification is a method for improving bone response to implant and increasing implant osseointegration. However, the currently applied modifications such as hydroxyapatite ...
متن کاملSuperior fixation of pegged trabecular metal over screw-fixed pegged porous titanium fiber mesh
BACKGROUND AND PURPOSE Lasting stability of cementless implants depends on osseointegration into the implant surface, and long-term implant fixation can be predicted using radiostereometric analysis (RSA) with short-term follow-up. We hypothesized that there would be improved fixation of high-porosity trabecular metal (TM) tibial components compared to low-porosity titanium pegged porous fiber-...
متن کاملCementless femoral fixation in total hip arthroplasty.
Cementless femoral fixation by means of bone ingrowth has been successful in total hip arthroplasty in patients with sufficient bone quality. Consistent bone ingrowth and resultant long-term success involve many factors, including surgical technique, initial mechanical stability achieved at time of implantation, stem design and material, and implant surface. One potential method for achieving f...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 35 شماره
صفحات -