Calibration of Large Square Standards

نویسنده

  • J. Mokroš
چکیده

In this paper the principle and device NME 90 for large square standards calibration is described. The self-calibration methods of measurement are used. They allow very low uncertainty of the square calibration with mathematical elimination of measuring column straightness deviations. The process of measurement is full automated and controlled by PC, which collects and evaluates measured data. The uncertainties of the square measurement are also discussed in the paper.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Improved Photometric Standards and Calibration Procedures at NIST

NIST has recently established a detector-based luminous intensity unit (candela, cd), which is derived from the NIST absolute cryogenic radiometer. Subsequently, the luminous flux unit (lumen, lm) and the luminance unit (cd/m2) have been established based on the detector-based candela, and now all the NIST photometric units are tied to the cryogenic radiometer. The illuminance unit is realized ...

متن کامل

Review and Comparison of In-field Calibration Methods of Accelerometer Based on Gravity Vector

Considering the wide applications of accelerometers to determine position and attitude and due to reducing of accuracy of this sensors because of some errors, this paper discusses the calibration of accelerometers. Also because the traditional calibration methods are very time consuming, costly and need precision laboratory equipment, in-field calibration methods are recommended which are simpl...

متن کامل

Accrediting Artifact Calibration of a Multi-Function Calibrator

A decade ago, two companies introduced electronic instruments incorporating Artifact Calibration, a technology by which an instrument calibrates itself using a small number of external standards, thereby significantly reducing the cost of calibration and simplifying their path of traceability. Some national standards laboratories have been cautious about accepting Artifact Calibration, perhaps ...

متن کامل

Standard calibration of ionization chambers used in radiation therapy dosimetry and evaluation of uncertainties

Background: Absolute dosimetry of external beam radiotherapy is carried out by the use of ionization chambers. These chambers must be calibrated at a standard dosimetry laboratory before any use in clinical dosimetry. The secondary standard dosimetry laboratory of Iran (SSDL) has the duty of calibrating the ionization chambers used in radiotherapy centers in Iran. Materials and Methods...

متن کامل

Spectral Radiance of a Large-Area Integrating Sphere Source

The radiance and irradiance calibration of large field-of-view scanning and imaging radiometers for remote sensing and surveillance applications has resulted in the development of novel calibration techniques. One of these techniques is the employment of large-area integrating sphere sources as radiance or irradiance secondary standards. To assist the National Aeronautical and Space Administrat...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001