7-amino-4-azaheptyl grafted onto a silica gel as a sorbent for the on-line preconcentration and determination of iron(III) in water samples.

نویسندگان

  • Sandra V M de Moraes
  • Mateus M Tisott
  • Caroline D Milcharek
  • Jorge L Brasil
  • Tania M H Costa
  • Márcia R Gallas
  • Edilson V Benvenutti
  • Eder C Lima
چکیده

A new sorbent was synthesized by anchoring 7-amino-4-azaheptyltrimetoxisilane, freshly prepared, to silica gel, producing 7-amino-4-azaheptyl anchored silica gel (AAHSG). This material was characterized by infrared spectroscopy (IR), elemental analysis (CHN), and nitrogen adsorption-desorption isotherms. Isotherms of the adsorption of Fe3+, Fe2+ and Cu2+ on AAHSG were recorded, which indicated that Fe3+ presents a higher affinity by the sorbent. Therefore, AAHSG was successfully employed as a sorbent in a simple flow system for the preconcentration of Fe3+ in natural water samples, such as, river water, lagoonwater, springwater, stream water, well water and two water reference materials (NIST-SRM 1640, NIST-SRM 1643d). The obtained preconcentration factor was 82.2, and the detection limit achieved was 5.9 ng ml(-1). The recovery of spiked water samples ranged from 95.0 - 103.1%.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Preconcentration and Determination of Chromium (III) from Sea Water Samples Using Ion Imprinted Activated Carbon

A simple ion imprinted amino-functionalized sorbent was synthesized by coupling activated carbon with iminodiacetic acid, a functional compound for metal chelating, through cyanoric chloride spacer. The resulting sorbent has been characterized using Fourier transform infrared spectroscopy (FT-IR), elemental analysis, thermogravimetric analysis (TGA) and evaluated for the preconcentration and de...

متن کامل

Preconcentration and Determination of Chromium (III) from Sea Water Samples Using Ion Imprinted Activated Carbon

A simple ion imprinted amino-functionalized sorbent was synthesized by coupling activated carbon with iminodiacetic acid, a functional compound for metal chelating, through cyanoric chloride spacer. The resulting sorbent has been characterized using Fourier transform infrared spectroscopy (FT-IR), elemental analysis, thermogravimetric analysis (TGA) and evaluated for the preconcentration and de...

متن کامل

Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...

متن کامل

Preconcentration and Determination of Mefenamic Acid in Pharmaceutical and Biological Fluid Samples by Polymer-grafted Silica Gel Solid-phase Extraction Following High Performance Liquid Chromatography

Abstract Mefenamic acid is a nonsteroidal anti-inflammatory drug (NSAID) that has analgesic,anti-infammatory and antipyretic actions. It is used to relieve mild to moderate pains. Solid-phase extraction of mefenamic acid by a polymer grafted to silica gel is reported . Poly allyl glycidyl ether/iminodiacetic acid-co-N, N-dimethylacrylamide was synthesized and grafted to silica gel and was used ...

متن کامل

Application of Modified Nanoclay Sorbent for Separation and Preconcentration Trace Amount of Cobalt

The present article reports on the application of modified organo nanoclay as a green, easily prepared and stable solid sorbent for the preconcentration of trace cobalt ion in aqueous solution. The organo nanoclay was modified by adsorption of 5-(4-dimethyl amino-benzylidene) rhodanin reagent onto it. The sorption of Co2+ ions was quantitative in the pH range of 7.0 to 8.5, whereas quantitative...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 21 5  شماره 

صفحات  -

تاریخ انتشار 2005